Pergola Planning Permission in Berlin, Hamburg and Bremen: The City States Compared
7 minutes read
In Berlin, Hamburg and Bremen, a patio cover, and with it usually a louvred pergola, is possible without a building permit up to 30 m² of area if a depth limit is observed: 3 m in Berlin and Hamburg, 3.50 m in Bremen. Setback distances, the development plan and heritage protection apply regardless. In densely built city states, it is often proximity to the boundary, not the area, that decides.
This article compares the rules on pergola permits in Berlin, Hamburg and Bremen (as of September 2026). It covers German state law only; if you live elsewhere, please check your local rules with the building authority. For an overview of all German states, see Does a pergola need a building permit?.
Pergola planning permission in Berlin, Hamburg and Bremen at a glance
| Berlin (BauO Bln) | Hamburg (HBauO) | Bremen (BremLBO) | |
|---|---|---|---|
| Reference | § 61 (1) No. 1 g | Annex to the HBauO, permit-exempt projects | § 61 (1) No. 1 h |
| Max. area | 30 m² | 30 m² | 30 m² floor area |
| Max. depth | 3 m | 3 m | 3.50 m |
| Conservatory also covered | No | No | Yes, predominantly glazed extensions |
| Standard setback depth | 0.4 H, min. 3 m | 0.4 H, min. 2.50 m | 0.4 H, min. 3 m |
All figures as of September 2026. Depth is generally measured from the house wall.
Berlin: 30 m² and 3 m depth
In Berlin, under § 61 (1) No. 1 g BauO Bln, "patio covers with an area of up to 30 m² and a depth of up to 3 m" are exempt from the permit procedure. Both values apply together: a structure of 10.0 × 3.0 m is exempt, one of 7.0 × 3.5 m (24.5 m²) is not, even though it is smaller.
The building code also lists open pergolas under "minor structures" in § 61 (1) No. 15 d, along with awnings, terraces and entrance canopies. A watertight louvred roof, however, is generally classed by the building control offices as a patio cover. Plan for 3 m depth, therefore.
Setback distances: Under § 6 (5) BauO Bln, the depth is 0.4 H, at least 3 m. Under § 6 (8), garages and buildings without habitable rooms and fireplaces may be built without their own setback area with an average wall height of up to 3 m and a length of 9 m per property boundary; 15 m in total is permitted. Whether a patio cover falls under this special rule is clarified by the district building control office.
A Berlin particularity: building control rests with the twelve district offices. Development plans, preservation ordinances and heritage areas differ considerably from district to district.
Hamburg: new building code since 2026
A newly worded building code has applied in Hamburg since 1 January 2026. It chiefly brings easier rules for solar installations, heat pumps and charging stations, as well as for building within the existing stock. According to the sources available, nothing significant has changed in the limit for patio covers: coverings of terraces remain exempt up to 30 m² of area and 3 m of depth.
Because the sections were renumbered, older guides still refer to § 60 HBauO and the former Annex 2. When researching, make sure you have the current version in front of you.
Setback distances: In Hamburg, the setback depth is 0.4 H, at least 2.50 m. That is slightly less than in Berlin and Bremen, but it does not change the fact that a louvred roof on the boundary regularly has to be checked.
A Hamburg particularity: many neighbourhoods lie in areas with preservation ordinances or within the scope of old stage plans (Baustufenpläne). Ask the district office which planning applies to your plot.
Bremen: 3.50 m depth, conservatories too
The Bremen State Building Code takes a wider view. Exempt are "terraces including any coverings, as well as predominantly glazed extensions intended only for temporary occupation (verandas, conservatories)" up to 30 m² of floor area and 3.50 m of depth. That also covers unheated conservatories of this size in Bremen, and 50 cm more depth than in Berlin and Hamburg.
Setback distances: Under § 6 (5) BremLBO, the depth is 0.4 H, at least 3 m. Garages and buildings without habitable rooms and fireplaces are permitted in the setback area with an average wall height of up to 3 m and a length of 9 m per property boundary.
A Bremen particularity: the typical terraced houses with narrow gardens (the "Bremer Haus") leave hardly any distance at the sides. Here, a structure across the full plot width can often only be realised in agreement with the neighbours and the building control authority. The rules apply equally to Bremen and Bremerhaven; the local building control authority is responsible in each case.
Measuring area and depth correctly
Because the city states work with a depth limit, a few centimetres can matter. Some practical notes:
- Depth: This is usually measured from the house wall to the outer edge of the cover, including the gutter or end profile, not just to the centre of the post.
- Area: Work with the outer dimensions of the roof surface. A structure of 10.0 × 3.0 m is exactly 30 m² and sits on the limit; it is better to plan with a little margin.
- Freestanding structures: For pergolas without a wall connection, "depth" is not clearly defined. Clarify with the building control office which dimension it applies.
- Several structures: Two covers side by side are generally considered together if they form one structural unit.
Record the measured values in a simple sketch. It helps with queries from the authority and when ordering.
What to watch in all three city states
- Terraced and semi-detached houses: The side boundary often lies directly at the terrace. Before ordering, check whether the structure can be set back from the boundary or whether you need a derogation. Notes are in Pergola on the property boundary.
- Roof terrace and balcony: The rules above concern ground-level terraces. Roof terraces have different structural and permit requirements; see Pergola on a roof or balcony.
- Development plan and preservation area: Design requirements also apply to permit-exempt projects. Details in Development plan and pergola.
- Condominium ownership: In apartment buildings, the owners' association decides on structural alterations.
- Wind load: In Hamburg and Bremen, wind load is an important design criterion because of the proximity to the coast.
This comparison reflects the law as of September 2026. The development plan and the advice of the competent district building control authority are binding; the article does not replace legal advice.
Checklist for your city terrace
- Fix the dimensions: area under 30 m², depth under 3 m (Berlin, Hamburg) or 3.50 m (Bremen)?
- Measure the distance to all property boundaries and compare it with the standard depth.
- Ask the district office about the development plan, preservation and heritage status.
- For terraced houses: inform the neighbours early and clarify drainage.
- Request the structural proof for wind and snow load from the manufacturer.
Plan a louvred roof for city gardens
In the configurator you can enter width and depth exactly, for example 6.0 × 2.95 m for Berlin or 8.5 × 3.45 m for Bremen, and check directly whether you stay within the limits. All variants of the bioclimatic pergola are also available for narrow terraced-house gardens.
Frequently asked questions
How large can a patio cover be in Berlin without a permit?
Under § 61 (1) No. 1 g BauO Bln, patio covers with an area of up to 30 m² and a depth of up to 3 m are exempt from the permit procedure (as of September 2026). Both limits must be met at the same time.
What changed in Hamburg in 2026?
A newly worded Hamburg Building Code (Hamburgische Bauordnung) has applied since 1 January 2026. Patio covers remain exempt up to 30 m² of area and 3 m of depth; the entries now appear in the annex to the new HBauO.
Why is Bremen more generous on depth?
The BremLBO covers terraces including any coverings, as well as predominantly glazed extensions such as conservatories, up to 30 m² of floor area and 3.50 m of depth. That makes 50 cm more depth exempt in Bremen than in Berlin or Hamburg.
Does the exemption also apply to pergolas on the property boundary?
Being exempt from the permit procedure does not mean setback distances fall away. In all three city states you must comply with the setback distances or the special rules for boundary structures; if in doubt, the district building control office will clarify.
Sources
- BauO Bln, § 61 Verfahrensfreie Bauvorhaben(opens in a new tab)
- BauO Bln, § 6 Abstandsflächen(opens in a new tab)
- Hamburgische Architektenkammer: Neue Hamburgische Bauordnung in Kraft getreten(opens in a new tab)
- Bremische Landesbauordnung, Gesetzblatt der Freien Hansestadt Bremen 2018(opens in a new tab)
- Pergola-Ratgeber: Baugenehmigung nach Bundesländern (Stand August 2026)(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.