Pergola Planning Permission in Lower Saxony: What the NBauO Requires for Patio Covers
6 minutes read
In Lower Saxony, a patio cover (which as a rule includes a louvred pergola) has been exempt from the permit procedure up to 40 m² of floor area since 1 July 2025, provided it keeps at least 3 m from the boundary of the neighbouring property. If both conditions are met, you need no building application. If the structure moves closer to the boundary, the exemption falls away.
This article explains the rules on pergola permits in Lower Saxony under the Lower Saxony Building Code (Niedersächsische Bauordnung, NBauO), as of September 2026. It covers German state law only; if you live elsewhere, please check the local rules with your building authority. For how other German states handle this, see the overview Does a pergola need a building permit?.
Pergola planning permission in Lower Saxony: the rule in No. 1.8
The NBauO lists permit-exempt building work in an annex to § 60 (1). Since the amendment of 1 July 2025, No. 1.8 reads in essence:
- Patio covers of no more than 40 m² floor area,
- conservatories of no more than 30 m² gross floor area and 5 m in height,
- in each case only if they keep at least 3 m from the boundary of the neighbouring property,
- plus balcony glazing and balcony roofs up to 30 m² floor area.
Before the amendment, the limit for patio covers was 30 m². At 40 m², Lower Saxony is now one of the most generous states, but with a condition many people overlook: the fixed boundary distance.
No depth limit
Unlike Berlin, Hamburg or Saxony, for example, the NBauO sets no maximum depth for patio covers. A louvred roof of 7.0 × 5.5 m (38.5 m²) is therefore generally exempt as long as the distance is right.
Worked examples
| Structure | Floor area | Distance to neighbouring boundary | Result under No. 1.8 |
|---|---|---|---|
| 5.0 × 4.0 m | 20 m² | 4.5 m | Exempt |
| 7.0 × 5.5 m | 38.5 m² | 3.2 m | Exempt |
| 8.0 × 5.5 m | 44 m² | 5.0 m | Building application needed (area) |
| 5.0 × 3.5 m | 17.5 m² | 1.5 m | Building application needed (distance) |
What counts is the actual floor area of the cover including frame and gutters. Measure the distance from the outermost edge of the structure to the property boundary.
Open pergola: garden design under No. 9.1
A classic, open pergola can be classified differently. Under Annex No. 9.1, structures that serve garden use or garden design (benches, seating groups, terraces and pergolas are expressly named) are exempt from the permit procedure, except buildings and enclosures.
For a bioclimatic pergola with aluminium louvres, however, this is usually not the right route. As soon as the louvres are closed, a watertight roof surface results and the structure behaves like a patio cover. To be on the safe side, plan under No. 1.8.
Boundary distances under § 5 NBauO
In addition to the condition in No. 1.8, the general distance rules of the NBauO apply:
- Standard distance: Under § 5 (2), the distance is 0.4 H, but at least 3 m.
- Projecting components: § 5 (3) allows minor encroachments, such as roof overhangs of up to 0.50 m.
- Boundary structures: Under § 5 (8), garages and buildings without habitable rooms up to 3 m in height, among others, are permitted without a setback or with a reduced one, on no more than 9 m per boundary and 15 m in total.
Whether a patio cover standing directly against the garage or the boundary can be permitted under § 5 (8) is a case-by-case question. In that situation it is in any event not exempt under No. 1.8, so you will need a building application.
What still applies despite the exemption
Permit-exempt building work must still comply with all public building law. In Lower Saxony, the building authorities say so explicitly. Please check:
- Development plan: Building lines, site coverage ratio and local building rules apply even without a building application. More in Development plan and pergola.
- Structural safety: The structure must safely carry the snow and wind loads at its location. Conditions differ markedly between the North Sea coast and the Harz.
- Heritage protection: For listed buildings or their surroundings, a permit under the Lower Saxony Monument Protection Act must be clarified.
- Drainage: Rainwater must not be directed onto the neighbouring property.
- Condominium ownership: In an owners' association, a resolution is generally needed.
Wind on the coast, snow in the Harz
Lower Saxony stretches from the East Frisian Islands to the Upper Harz. On the coast and the islands, wind mainly determines the design; at higher altitudes in the Harz, snow load is the bigger factor. Ask the manufacturer for the permissible loads and have it confirmed that posts, foundations and fixings are designed for your location. Background is explained in Wind load and pergola.
If a building application is needed after all
If your structure exceeds 40 m² or falls short of the 3 m distance, that is no reason to abandon the project. You will, however, need a procedure with the lower building control authority, depending on location in the simplified building permit procedure. Typically this involves:
- an official site plan showing the structure and distances,
- floor plan, elevations and section with heights,
- a specification with materials,
- a structural safety proof if the authority requires one,
- where building on the boundary, possibly a declaration or building encumbrance (Baulast) from the neighbour.
The application documents generally have to be submitted by a person entitled to submit building plans, such as an architect or a structural engineer. Allow several weeks for preparation and review, and order the pergola only once the permit is in hand or the authority has confirmed the exemption.
Check variants close to the boundary
Often the exemption can be achieved with small changes: the structure is made 30 cm narrower, moved away from the fence, or split into two modules of which only one adjoins the house wall. Work through such variants before commissioning documents for a building application.
Conservatory instead of pergola?
No. 1.8 also covers conservatories, with stricter limits (30 m², 5 m height) and the same 3 m distance. If you later want to enclose a louvred pergola on all sides with sliding glass walls, you may shift the classification towards a conservatory. The smaller area limit then applies. The differences in permits and use are explained in Pergola and conservatory.
Checklist for Lower Saxony
- Calculate the floor area of the structure: up to 40 m²?
- Measure the distance from every outer edge to the neighbouring boundary: at least 3 m?
- Clarify the classification: open pergola, louvred roof or a conservatory enclosed later?
- Ask the municipality about the development plan and local building rules.
- Check heritage protection and the owners' association.
- Structure: compare the snow and wind load of the location with the manufacturer's figure.
- Close to the boundary or above 40 m²: prepare a building application through a person entitled to submit plans.
This information reflects the NBauO as of September 2026. The development plan and the advice of the lower building control authority of your district or city are decisive; this article does not replace legal advice.
Plan your louvred roof to suit the NBauO
With the configurator you set the width and depth of your pergola and see immediately whether you stay under 40 m². Equipment, colours and side elements are on the bioclimatic pergola page. Trade businesses carrying out several projects in Lower Saxony can request quotes for their customers through a B2B account.
Frequently asked questions
How large can a patio cover be in Lower Saxony without a building permit?
Since 1 July 2025, patio covers of no more than 40 m² of floor area are exempt from the permit procedure if they keep at least 3 m from the neighbouring property boundary (Annex No. 1.8 NBauO, as of September 2026).
Is there a depth limit for patio roofs in Lower Saxony?
No. The annex to the NBauO limits only the floor area of patio covers and requires a minimum distance of 3 m from the neighbouring boundary. There is no fixed depth as in some other German states.
What applies if my pergola stands closer than 3 m to the boundary?
Then No. 1.8 does not apply and the project generally needs a building permit. Whether it can be allowed as a boundary structure under § 5 (8) NBauO should be clarified with the lower building control authority.
Is a conservatory exempt from the permit procedure in Lower Saxony?
Under No. 1.8, conservatories are exempt up to 30 m² gross floor area and 5 m in height, again only with at least 3 m to the neighbouring boundary. For heated conservatories, energy requirements must also be checked.
Sources
- NBauO, Anhang (zu § 60 Abs. 1) Verfahrensfreie Baumaßnahmen(opens in a new tab)
- NBauO, § 5 Grenzabstände(opens in a new tab)
- Ingenieurkammer Niedersachsen: Novelle der NBauO – das ist seit dem 1. Juli 2025 neu(opens in a new tab)
- Stadt Wolfsburg: Infoblatt verfahrensfreie Baumaßnahmen 2025(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.