Front Door U-Value: Requirements, Guide Values and What Affects the Figure

7 minutes read

A front door's U-value (more precisely, its U_D value) tells you how much heat is lost through the complete door. In Germany, a new external door fitted to an existing building may legally have no more than 1.8 W/(m²K); anyone wanting funding or the tax bonus needs 1.3 W/(m²K) at most (as at September 2026). Well-insulated front doors today reach values around 1.0 W/(m²K) and below. The legal and funding rules in this article apply to Germany; readers elsewhere should check their own national building regulations.

What a Front Door's U-Value Tells You

The heat transfer coefficient describes how much heat energy flows through a building element per square metre for each degree of temperature difference. Unit: W/(m²K). The smaller the figure, the better the door insulates.

For doors, a distinction is made between:

  • U_D (door): the value for the whole door: outer frame, leaf, infill, glass and threshold.
  • U_f (frame): the value for the frame profile only.
  • U_g (glass): the value for the glazing only.

For legal requirements and funding programmes, only the U_D value of the complete door counts. A brochure quoting only a low U_f value for the profile therefore says little about the finished door. Look at the declaration of performance or the data sheet for the specific model in the size ordered.

Since 29 July 2026 the Gebäudemodernisierungsgesetz (GModG) has applied, replacing the former Gebäudeenergiegesetz. The maximum values for building elements when existing buildings are altered are still set out in Annex 7. For newly fitted external doors it provides:

  • Maximum U = 1.8 W/(m²K), relating to the door area.
  • The value applies both to residential buildings and to zones of non-residential buildings.
  • Exempt are frameless glass door systems, revolving doors and power-operated doors.

This value is a lower limit of quality. Practically every insulated front door offered today falls well below it. In new buildings the requirement follows the overall energy balance of the building; the door's value feeds into that calculation.

Funding Level: 1.3 W/(m²K)

The federal funding for efficient buildings (BEG) also supports, via BAFA, the replacement of external doors as an individual measure on the building envelope. One condition is an external door U-value of no more than 1.3 W/(m²K). The same limit applies to the tax reduction under § 35c EStG.

Requirement External door U-value As at
GModG, Annex 7 (fitting in existing buildings) ≤ 1.8 W/(m²K) September 2026
BEG individual measure (BAFA) ≤ 1.3 W/(m²K) September 2026
Tax bonus § 35c EStG ≤ 1.3 W/(m²K) September 2026

Some of the funding conditions changed on 21 July 2026. What currently applies is explained in the article on front door grants.

Typical Values by Material

The door manufacturer FeBa gives these typical ranges:

  • uPVC front doors: about 0.8 to 1.2 W/(m²K)
  • Aluminium front doors: about 0.9 to 1.4 W/(m²K)
  • Timber and timber-aluminium: about 0.9 to 1.3 W/(m²K)

The ranges overlap heavily. The material is therefore not the only factor; within each group there are doors that clearly beat the funding level and others that miss it. More on comparing materials in the article on aluminium vs uPVC front doors.

What Affects the U_D Value

Infill

The infill makes up most of the door area. Thick infills with a rigid foam core insulate best. Leaf-covering infills usually allow more insulation thickness than inset ones; see front door infills compared.

Glazed Area

Glass insulates less well than a foamed infill. The larger the glazed cut-out, the higher the U_D value tends to be. Triple glazing with a warm edge softens the effect. The same applies to sidelights with a lot of glass.

Profile and Threshold

With aluminium, the thermal break created by insulating bars provides good thermal performance; with uPVC it is the chamber structure. According to FeBa, a thermally broken threshold can improve the U_D value by 0.1 to 0.3 W/(m²K).

Seals and Fitting

The U-value takes account only of heat conduction. Draughts through leaky joints come on top. Several continuous seal layers and an airtight connection to the wall are therefore just as important as a good calculated value.

Size

The U_D value also depends on size, because the ratio of frame to infill changes. Make sure the stated value matches your order size or that the manufacturer confirms the value for your dimensions.

How the U_D Value Is Determined

Front doors fall under the European product standard DIN EN 14351-1 for windows and external doors. The manufacturer states the heat transfer coefficient in its declaration of performance. It is determined either by calculation from the values for frame, infill and glass (to DIN EN ISO 10077) or by measurement on a test rig.

For you this means:

  • Ask for the value for the specific configuration. A catalogue value often refers to a particular model in a reference size.
  • For grant applications, the energy efficiency expert needs the manufacturer's data to confirm compliance with the technical minimum requirements.
  • Values quoted without the size or design are only of limited use for comparison.

Sidelights and Fanlights

With a door unit that has a sidelight or fanlight, the fixed elements have their own characteristic values, especially when glazed. Clarify with the energy efficiency expert how the unit is assessed for funding, and ask for the values for all parts. Large glazed sidelights in particular can worsen the overall result for the unit.

Is a Particularly Low U-Value Worth It?

A front door has only a small area compared with windows and walls. The difference between 1.1 and 0.8 W/(m²K) therefore has a limited effect on heating costs. What you will notice is:

  • Comfort: a well-insulated door has a warmer inside surface and the hallway is less draughty.
  • Condensation: low surface temperatures on the frame or threshold can lead to condensation in winter.
  • Funding eligibility: you should in any case plan for the funding level of 1.3 W/(m²K).

Surface Temperature and Condensation

Critical spots are above all the threshold and the junction with the floor and reveal. Cold building surfaces encourage condensation in winter and, in the worst case, mould. A thermally broken threshold and an insulated, airtight installation joint help keep these spots warm. More on this in the article on door thresholds on front doors.

Checklist: Checking the U-Value Properly

  • U_D value of the complete door stated, not just the U_f of the profile
  • Value applies to your size and your design with glazed cut-out
  • Sidelights and fanlight considered separately
  • 1.3 W/(m²K) or better if you want to claim funding or § 35c
  • Thermally broken threshold and several seal layers
  • Fitting with an airtight connection agreed

Compare the characteristic values of the front doors in the shop and put together infill, glass and sidelights in the configurator. For projects seeking funding, request the U_D value for your order size in writing.

Frequently asked questions

What U-value must a new front door legally have?

In Germany, when a new external door is fitted to an existing building, its U-value must not exceed 1.8 W/(m²K) under Annex 7 of the Gebäudemodernisierungsgesetz (as at September 2026).

Which U-value is needed for funding?

For BEG individual measures and the tax bonus under § 35c EStG, an external door may reach 1.3 W/(m²K) at most. The current technical minimum requirements are what counts.

What is the difference between U_D and U_f?

U_D (D for door) describes the heat transfer of the complete door including frame, infill and glass. U_f applies only to the frame. For the law and for funding, the U_D value of the whole door is what counts.

Does a glazed cut-out worsen the front door's U-value?

As a rule, yes, because glass usually insulates less well than a foamed infill. With triple glazing and a warm edge, however, the effect stays limited. Check the value for your specific design.

Sources

  1. Gebäudemodernisierungsgesetz (GModG), Anlage 7 – Höchstwerte der Wärmedurchgangskoeffizienten(opens in a new tab)
  2. Bundesregierung – Neues Gebäudemodernisierungsgesetz(opens in a new tab)
  3. BAFA – Einzelmaßnahmen an der Gebäudehülle(opens in a new tab)
  4. FeBa – Ud-Wert der Haustür erklärt(opens in a new tab)
  5. Steuerschröder – § 35c EStG und technische Anforderungen(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

Cover image: Security Front Door RC2: Classes and Locking
Front doors

Security Front Door RC2: Classes and Locking

Security front door RC2 or RC3? What the resistance classes to DIN EN 1627 test, which locking is worthwhile and what to look for when you buy.

7 minutes read

We use strictly necessary cookies so the shop, configurator and basket work. With your consent we also use Google Analytics to measure how the site is used, and marketing signals for advertising. You can change your choice at any time in the footer. Read our privacy policy