The front door threshold has to fulfil two opposing tasks: it should keep wind, rain and cold out, and at the same time be as low as possible so that nobody trips and wheelchairs or walkers can pass unhindered. For accessible doors under the German standard DIN 18040-2, 2 cm is the maximum permitted. With magnetic seals, drop-down bottom seals, a channel in front of the door and a canopy, low thresholds can nevertheless be made weathertight. The standards and funding conditions quoted are German; elsewhere, check your national accessibility requirements.

Why the Threshold Is a Conflict of Aims

A high threshold forms a natural stop: the leaf seal rests against it, water is held back and wind has no direct path. The lower the threshold, the more the seals, drainage and construction have to take over these tasks.

Threshold type Height (typical) Weather tightness Accessibility
Classic stop threshold several centimetres very good limited
Low aluminium threshold up to approx. 2 cm good with a suitable seal meets DIN 18040-2
Zero threshold with magnetic seal flush with floor good if the surroundings are right very good
Drop-down bottom seal flush with floor good with a sheltered entrance very good

The Standard Values

  • DIN 18040-2 (barrier-free housing): lower door stops and thresholds are not provided for. Where they are technically unavoidable, they may be no more than 2 cm high; edges should be bevelled or rounded.
  • KfW loan 159 (barrier reduction): the technical minimum requirements specify threshold-free construction for entrance doors or, where not structurally possible, thresholds of 20 mm at most.
  • Trade practice without an accessibility requirement: a technical article on defects in front doors names a maximum threshold height of 25 mm above finished floor level as common practice.

Which height makes sense for you depends on use and location. Anyone planning for accessibility or later life should not exceed 2 cm; see accessible front doors.

Low and Weathertight Front Door Thresholds: The Techniques

Magnetic Double Seal

A magnet sits in the leaf and a movable seal with a metal strip in the threshold. As the door closes, the magnet pulls the seal up against the leaf. The threshold stays almost flush with the floor, yet the seal still makes contact. Important: keep the guide clean so that small stones do not block the seal.

A sealing strip in the lower leaf profile lowers onto the floor as the door closes, triggered by a release on the hinge side. When the door opens, it lifts again. This solution works well on sheltered entrances; in driving rain on the weather side it needs support from a canopy and channel.

Low Threshold with Stop

A low aluminium threshold of up to 2 cm with bevelled edges forms a small stop for the leaf seal. This is a proven compromise between weather protection and ease of rolling over.

Water: The Surroundings Decide

The lower the threshold, the more important it is that water does not reach the door in the first place:

  • Canopy: considerably reduces driving rain on leaf and threshold; see canopies and entrance areas. A technical article recommends a canopy or porch for unprotected doors on the weather side.
  • Fall: landing and path must slope away from the door.
  • Drainage channel: a channel with a grating directly in front of the threshold catches water before it reaches the door. It must be connected to a drain.
  • Sealing of the connection: the sealing standards for elements in contact with the ground, balconies and terraces provide, at doors, in principle for an upstand above the water-bearing layer. Lower or level connections are possible as a special solution with additional measures and should be expressly agreed between planner and contractor.

The basics of level transitions at patio doors are described in the article on sealing a zero threshold properly; the principles apply by analogy to front doors.

Heat: The Threshold as a Thermal Bridge

The threshold sits at the transition from the cold outer surface to the warm floor. If it is made of continuous metal, it conducts cold inwards. The consequences can be cold feet in the hallway, condensation and, in the worst case, mould.

  • Thermally broken thresholds have an insulating bar between the outer and inner parts. According to FeBa, such a threshold can improve the door's U_D value by 0.1 to 0.3 W/(m²K).
  • Minimum surface temperature: the technical article mentioned refers, for the connection to the structure, to a temperature factor f_Rsi of at least 0.70 to DIN 4108-2 and describes steel angles as threshold substructure as a critical thermal bridge.
  • Insulated substructure: beneath the threshold there should be a load-bearing, insulated substructure rather than concrete or steel.

More on the thermal performance of the whole door in the article on the U-value of a front door.

Retrofitting: Lowering a High Threshold?

An existing high threshold can be changed only to a limited extent:

  • With some systems the threshold can be swapped for a flatter profile. This depends on the frame and must be clarified with the manufacturer.
  • Outside, a ramp or a raised landing can make up the height difference, but then with a channel in front of the door.
  • Inside, transition profiles or an adapted floor covering help.

Replacing the door is often the cleaner solution, above all if insulation and security are to be improved at the same time.

Which Solution for Which Entrance?

  • Sheltered entrance under a canopy or in a porch: zero threshold with magnetic seal or drop-down bottom seal, with maximum comfort and good weather tightness.
  • Weather side without cover: low threshold up to 2 cm with a stop, plus a channel and, if possible, a retrofitted canopy.
  • Entrance with external steps: accessibility is limited here anyway; a somewhat higher threshold can make sense, provided there are no accessibility requirements.
  • Accessible new build: plan threshold-free construction from the start with floor slab, sealing and drainage; doing it afterwards is considerably harder.

Inside: The Transition to the Floor Covering

The threshold must also connect cleanly on the inside. The finished floor covering in the hallway should meet the threshold flush or with a low transition profile. Allow for the thickness of the covering before ordering the door, because a thick covering laid afterwards can cause the door to drag on the floor or a drop-down seal no longer to trigger properly. With underfloor heating, the heating circuit should not extend under the threshold, so that no heat flows directly outwards.

Looking After the Threshold

  • Regularly remove dirt, leaves and small stones from seals and guides.
  • Keep drainage openings in the threshold clear.
  • Clean channels in front of the door, especially in autumn.
  • Keep seals supple with a suitable care product so that they stay elastic even in frost.
  • Check drop-down seals once a year for the correct trigger point.

Checklist for the Right Threshold

  • Use clarified: accessible (max. 2 cm) or classic threshold
  • Sealing system chosen: stop, magnetic seal or drop-down seal
  • Canopy and fall in front of the door planned
  • Drainage channel for low thresholds
  • Sealing of the connection agreed with planner and contractor
  • Thermally broken threshold, insulated substructure
  • Care of seals and channel allowed for

You choose the threshold specification together with model and dimensions in the configurator. You can see which models with low-barrier thresholds are available among the front doors.

Frequently asked questions

How high may a front door threshold be?

For accessible doors under DIN 18040-2, thresholds are not provided for; where technically unavoidable, they may be no more than 2 cm high. Without an accessibility requirement, higher thresholds are possible, which make weather protection easier.

Is a front door without a threshold weathertight?

Yes, if the system is designed for it. Magnetic double seals or drop-down bottom seals close the gap when the door shuts. A fall, a drainage channel in front of the door and, if possible, a canopy are important as well.

What is a thermally broken threshold?

A threshold in which the outside and inside are separated by an insulating bar. It reduces heat loss and keeps the inside warmer, which prevents condensation. According to the door manufacturer FeBa, it can improve the U_D value by 0.1 to 0.3 W/(m²K).

Why does condensation form on my threshold in winter?

Usually the threshold or its connection is a thermal bridge. The surface cools so much that indoor humidity condenses. Remedies are thermally broken thresholds, insulated connections and sufficient ventilation.

Sources

  1. nullbarriere.de – DIN 18040-2 Türen(opens in a new tab)
  2. bauhandwerk/BM – Die Haustür: ein Fall für den Gutachter(opens in a new tab)
  3. FeBa – Ud-Wert der Haustür erklärt(opens in a new tab)
  4. KfW – Technische Mindestanforderungen Altersgerecht Umbauen (159)(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

Cover image: Letterbox Sidelight or Door Letter Plate?
Front doors

Letterbox Sidelight or Door Letter Plate?

Letterbox in the sidelight, in the front door or outside? Pros and cons for insulation, security and convenience, plus EN 13724 sizes and planning tips.

7 minutes read

We use strictly necessary cookies so the shop, configurator and basket work. With your consent we also use Google Analytics to measure how the site is used, and marketing signals for advertising. You can change your choice at any time in the footer. Read our privacy policy