Patio Cover Permission in NRW: What the BauO NRW Says About Pergolas and Louvred Roofs
6 minutes read
A patio cover needs no permission in NRW (North Rhine-Westphalia, Germany) if it is at most 30 m² in area and at most 4.50 m deep. That is how § 62 para. 1 no. 1 g of the NRW state building code regulates it (as of September 2026). This also applies to pergolas with a louvred roof, because when closed the louvres form a roof. You must still comply with setback distances to the neighbour, the development plan and structural requirements. This article covers German law; readers in the UK or elsewhere should check the rules of their local planning authority.
The rule in its own words: § 62 BauO NRW
§ 62 BauO NRW lists all developments exempt from procedure. For terrace and garden, these points matter:
| Development | Reference | Limit |
|---|---|---|
| Patio covers | § 62 para. 1 no. 1 g | Area up to 30 m² and depth up to 4.50 m |
| Balcony glazing and balcony covers | § 62 para. 1 no. 1 g | up to 30 m² floor area |
| Conservatories | § 62 para. 1 no. 1 g | up to 30 m² gross floor area on buildings of building classes 1–3 |
| Pergolas (as minor structures) | § 62 para. 1 no. 15 f | no size stated |
| Buildings without habitable rooms | § 62 para. 1 no. 1 a | up to 75 m³ gross volume |
Compared with many other German states, NRW is generous on depth: 4.50 m also allows covers that reach far into the garden. The area limit of 30 m² remains binding, however. A cover 7 m wide and 4.50 m deep has 31.5 m² – and would therefore no longer be exempt.
Pergola, louvred roof or patio cover?
What counts for classification is not the product name but the construction:
- An open pergola without a roof – a climbing frame, for example – is a minor structure under no. 15 f.
- A louvred pergola forms a rainproof roof when the louvres are closed. It is therefore classed as a patio cover and must keep to the limits of no. 1 g. How such a system works is explained in the article on the bioclimatic pergola.
- If the sides are closed with glass, the structure can become a conservatory. The limit of 30 m² gross floor area then applies, and only for buildings of building classes 1 to 3.
Patio cover permission in NRW: setback distances
This is the most common source of error. The Bauportal NRW points out that a patio cover generally meets the definition of a building under § 2 para. 2 BauO NRW. The setback distances under § 6 therefore apply:
- Depth of the setback area: 0.4 H, at least 3 m (§ 6 para. 5). H is the wall height; for a pergola 2.80 m high, 0.4 H gives only 1.12 m – so the 3 m minimum is usually the deciding figure.
- Building on the boundary: setback areas are not required if planning-law regulations allow building on the boundary (§ 6 para. 1 sentence 3). This typically concerns semi-detached and terraced houses.
- Privileged boundary structures: § 6 para. 8 permits, without their own setback areas, buildings of up to 30 m³ gross volume without habitable rooms and garages, for instance, each with an average wall height of up to 3 m, at most 9 m per neighbouring boundary and 18 m in total. Patio covers are not expressly named there.
For detached houses, therefore, allow at least 3 m between the pergola and the neighbouring boundary unless provided otherwise. For details on measuring and special cases, see Pergola on the property boundary.
Development plan: the second test
A cover that is exempt under § 62 must also comply with the development plan. Pay particular attention to:
- Building lines: if the terrace lies outside the building window, a cover may be impermissible or require an exemption.
- Site coverage ratio (GRZ): a cover counts towards the built-over area. If the GRZ is exhausted, things get tight.
- Design requirements: some plans regulate roof shapes, colours or materials.
You will find the development plan at your town or municipality, often also online in the geoportal.
Structural design: exempt from procedure does not mean exempt from proof
The cover must safely carry snow and wind loads at the site. NRW lies mostly in low snow load zones, but in upland areas such as the Sauerland or the Eifel the values rise markedly. Have the supplier confirm which loads the structure is designed for at your dimensions. How the zones are structured is explained in the article Snow load on pergolas.
Worked examples for typical terraces
| Cover dimensions | Area | Depth | Exempt under no. 1 g? |
|---|---|---|---|
| 5.00 m × 4.00 m | 20.0 m² | 4.00 m | Yes |
| 6.00 m × 4.50 m | 27.0 m² | 4.50 m | Yes |
| 7.00 m × 4.50 m | 31.5 m² | 4.50 m | No – area exceeded |
| 5.00 m × 5.00 m | 25.0 m² | 5.00 m | No – depth exceeded |
The table covers only the size limits. You check setback distances and the development plan in addition.
If the limits are exceeded
If your desired pergola is larger, you need a building application. That is no obstacle, but it takes time and usually requires a person entitled to submit building documents, such as an architect. Alternatively, the plan can often be adjusted to stay under the limits – for example with a slightly smaller width. If in doubt, an informal enquiry or a preliminary building enquiry to the lower building authority helps.
Common misunderstandings in NRW
Several mistaken beliefs persist around the 30 m² rule:
- "Anything under 30 m² is allowed." Wrong. The size limit only governs the procedure. Setback distances, development plan, heritage protection and structural design remain – and so do neighbours' rights.
- "Nobody checks without a permit." The building authority can also inspect structures exempt from procedure, for example after a neighbour's complaint. If rules are broken, it can demand changes or removal.
- "The depth is measured from the post." What counts is the cover itself. A roof overhang beyond the posts counts too.
- "Side walls change nothing." Glass walls can turn an open cover into a conservatory – with its own limits and requirements.
- "The rules also apply to commercial use." For restaurants or businesses, further regulations may apply, such as on escape routes or changes of use.
Anyone who clarifies these points early saves rework – and trouble with the authority or neighbours.
Checklist for NRW
- Calculate the area and depth of the planned cover: at most 30 m² and 4.50 m.
- Decide on side elements – glazed all round may count as a conservatory.
- Measure the distance to every neighbouring boundary: as a rule at least 3 m.
- Check the development plan for building lines, GRZ and design requirements.
- Request structural proof for your snow and wind loads.
- For owned flats, obtain the resolution of the owners' association.
The development plan and the local building authority always have the final say; this article does not replace legal advice. How other states regulate the question is shown in our overview by state.
Next step
In the pergola configurator you enter width and depth to the millimetre and see immediately whether your plan stays within 30 m² and 4.50 m. Then choose colour, drive and equipment and request your quote.
Frequently asked questions
How large can a patio cover be in NRW without building permission?
Under § 62 para. 1 no. 1 g BauO NRW, patio covers with an area of up to 30 m² and a depth of up to 4.50 m are exempt from procedure (as of September 2026). Both values must be met.
How is the depth of a patio cover measured?
The usual measure is from the house wall to the front edge of the cover. For freestanding structures, it is best to ask the building authority which measurement it applies.
Can I build a patio cover right on the boundary in NRW?
Only if planning-law regulations allow or require building on the boundary, for example with terraced and semi-detached houses. Otherwise the setback distance of 0.4 H, at least 3 m, applies.
Is a conservatory also exempt from procedure in NRW?
§ 62 BauO NRW lists conservatories of up to 30 m² gross floor area on buildings of building classes 1 to 3 as exempt from procedure. Setback distances and the development plan apply here too.
Sources
- § 62 BauO NRW 2018 – Verfahrensfreie Bauvorhaben (Gesetzestext)(opens in a new tab)
- § 6 BauO NRW 2018 – Abstandsflächen (Gesetzestext)(opens in a new tab)
- Bauportal NRW: Verfahrensfreie Bauvorhaben nach § 62 BauO NRW 2018(opens in a new tab)
- Bauportal NRW: Terrasse mit und ohne Überdachung bauen in Nordrhein-Westfalen(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.