Pergola Planning Permission in Hesse: What the HBO Says About Exemption from Procedure
6 minutes read
In Hesse a pergola usually needs no building permission – but not without conditions. Under the annex to § 63 HBO (the Hessian Building Code), an open pergola is exempt from permission as a garden structure. A roofed pergola, for example with a louvred roof, counts as a cover over a ground-floor terrace: on buildings of building classes 1 to 3 it is exempt without a fixed area limit, provided a person entitled to certify confirms structural safety before building starts (as of September 2026). This article is about Hessian law in Germany; readers elsewhere, including in the UK, should check the rules of their own planning authority.
Hesse thus goes its own way: instead of a square-metre limit as in most other states, the HBO relies on a structural calculation. Here we explain what that means in practice.
The legal basis: § 63 HBO and its annex
In Hesse, § 63 HBO governs developments exempt from building permission; the individual cases are listed in the annex to § 63. The HBO was most recently amended by the "Baupaket I" (building package I), which according to Frankfurt's building supervisory authority came into force on 14 October 2025. Three entries are relevant to terraces and pergolas:
| Annex number (section I) | Content | Proviso |
|---|---|---|
| No. 1.12 | Conservatories up to 30 m² floor area on buildings of building classes 1 to 3 | Provisos nos. 1 and 3 |
| No. 1.13 | Covers and partial glazing of ground-floor terraces on buildings of building classes 1 to 3 | Proviso no. 3 |
| No. 9.1 | Garden-use and garden-design structures such as seating groups, pergolas, uncovered terraces up to 1 m high | – |
With the amendment, the provisos in the annex were renumbered: what used to be in section V is now in section IV. In substance, the reference for patio covers remained the same.
Pergola planning permission in Hesse: what the structural safety proviso requires
The decisive difference from other German states lies in proviso no. 3. According to the guide from the town of Münzenberg on the annex to § 63 HBO, it means that a person entitled to certify must confirm to the client before building starts that the cover is structurally sound.
For you as the client, this means:
- You need a structural engineer or another person entitled to certify who checks the structural design for your site.
- The basis is the snow and wind loads at the plot and the fixings to wall and ground.
- The certificate stays with you – it is not submitted to the authority, but should be producible at any time.
- Without this confirmation, the cover is not exempt from permission.
Manufacturers' data on snow and wind loads are an important basis, but do not automatically replace the certificate for your specific project. How snow loads are determined is explained in our article Snow load on pergolas.
Open pergola: simple, but not limitless
A classic pergola without a roof – for example as a climbing frame over a seating area – falls under section I no. 9.1 of the annex. It is exempt from building permission without a structural safety certificate being required. It must still be structurally sound, however.
As soon as the pergola gets a closed roof, no. 1.13 applies. A bioclimatic pergola with closed louvres is a patio cover in this sense.
Setback distances: 2.50 m since October 2025
In Hesse, "exempt from building permission" expressly does not mean "free of rules". § 63 HBO makes clear that developments exempt from permission must comply with public-law regulations. This chiefly includes § 6 HBO:
- The depth of the setback area is generally 0.4 H, but at least 2.50 m. Before the amendment the minimum depth was 3 m.
- Under § 6 para. 10 HBO, building directly on the boundary or at least 1 m from it is permitted for, among other things, garages and ancillary buildings for storage purposes – with an average wall height on the boundary side of up to 3 m and a total of at most 15 m of building along the boundary. A patio cover is not mentioned in this list.
In practice this means: a freestanding cover, or one attached to the house wall, should keep the setback distance of at least 2.50 m from the neighbouring boundary, unless the development plan provides otherwise or building on the boundary is permitted, as is often the case with terraced and semi-detached houses. More in the article Pergola on the property boundary.
Check the development plan and building class
Two further points decide whether the exemption applies:
- Building class: the exemption applies only to buildings of building classes 1 to 3. These are essentially freestanding and non-freestanding buildings of low height, typically detached and two-family houses, and semi-detached and terraced houses. For larger apartment buildings a procedure is needed.
- Development plan: if it contains provisions that rule out or restrict such developments – such as building lines, an exhausted site coverage ratio or design requirements – these also apply to the cover that is otherwise exempt. The Münzenberg guide expressly points out that the client is personally responsible for complying with all public-law regulations.
Side walls: when it becomes a conservatory
No. 1.13 allows covers and "partial glazing". If all sides are closed with glass, the structure can count as a conservatory. Under no. 1.12 this is exempt from permission only up to 30 m² floor area and is also subject to proviso no. 1 – according to the guide, a notification to the municipality with building documents and a waiting period. If you are planning sliding glass walls on your pergola, clarify the classification with the building authority beforehand.
Three typical cases from practice
The following examples show how the rules interact. They do not replace a case-by-case check, but they help with classification.
Detached house with a garden terrace
A louvred pergola 4 m wide and 3.5 m deep, attached to the house wall and open all round. The house belongs to building class 1, the development plan contains no restrictions, and the distance to the neighbouring boundary is 5 m. No. 1.13 applies here: you need no building application, but you do need the structural safety certificate before building starts.
Mid-terrace house with a narrow garden
The terrace extends from boundary to boundary. A cover across the full width abuts both neighbouring boundaries directly. Whether that is permitted depends on whether the development plan allows building on the boundary and what the neighbouring buildings look like. Clarify this case with the building authority before ordering and talk to your neighbours.
Cover with sliding glass walls
A pergola with glass walls on three sides and the house wall on the fourth is enclosed all round. Classification as a conservatory is likely here – with the 30 m² area limit and the additional proviso no. 1. Partial glazing, for example only on the weather side, is more likely to stay within no. 1.13.
Checklist for your pergola in Hesse
- Clarify the building class of your house (1 to 3?).
- Inspect the development plan at the municipality.
- Measure the distance to the neighbouring boundary – at least 0.4 H, but not less than 2.50 m.
- Open pergola or cover? For a cover, commission a structural engineer.
- Obtain the structural safety certificate before building starts and keep it.
- Agree side elements with the building authority.
- If heritage protection applies, involve the heritage authority.
The development plan and the local building authority always have the final say; this article does not replace legal advice. For a comparison with the rules of other states, see our overview by state.
Next step
For the structural engineer you need exact dimensions, post positions and the mounting type. In the pergola configurator you set width, depth and post height, choose a wall-mounted or freestanding version, and receive a configuration you can present to your structural engineer and the building authority. You can also use it to request your quote.
Frequently asked questions
Is there an area limit for permission-free patio covers in Hesse?
For covers over ground-floor terraces on buildings of building classes 1 to 3, the annex to § 63 HBO names no fixed square-metre limit. The exemption is, however, subject to a structural safety certificate (as of September 2026).
Who confirms the structural safety of a patio cover in Hesse?
A person entitled to certify, usually a structural engineer, confirms to the client before building starts that the structure is structurally sound. Keep this certificate.
How far from the boundary must a pergola be in Hesse?
If the cover counts as a building, the setback distance under § 6 HBO applies: 0.4 H, and since 14 October 2025 at least 2.50 m instead of the previous 3 m. The development plan may contain different provisions.
Does an open pergola without a roof need permission in Hesse?
Pergolas are listed in section I no. 9.1 of the annex to § 63 HBO as garden-use and garden-design structures and are therefore exempt from building permission. Other public-law regulations continue to apply.
Sources
- Hessisches Wirtschaftsministerium: HBO, Stand Oktober 2025 (Baupaket I)(opens in a new tab)
- Architekten- und Stadtplanerkammer Hessen: Synopse HBO-Änderung Baupaket I(opens in a new tab)
- Bauaufsicht Frankfurt: Infoschreiben zur HBO-Novelle (11.11.2025)(opens in a new tab)
- HBO Anlage zu § 63 – baugenehmigungsfreie Vorhaben (Textfassung)(opens in a new tab)
- Stadt Münzenberg: Leitfaden für baugenehmigungsfreie Vorhaben nach § 63 HBO(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.