Skip to content

Business customers only (B2B) · All prices net plus VAT

AluKun
Pergolas & planning rules

Wind Load and Pergolas: What Matters in Exposed Locations

6 minutes read

The wind load on a pergola depends on wind zone, terrain shape, height and construction. Under DIN EN 1991-1-4 with its German national annex, Germany is divided into wind zones 1 to 4; the basic velocity pressure ranges from 0.32 kN/m² in zone 1 to 0.56 kN/m² in zone 4. On coasts, on hilltops or in open fields, markedly higher forces act than in the sheltered garden of a housing estate. What matters is that structure, side elements and foundations are designed for your site. The zones here are the German ones; if you are in the UK or elsewhere, ask your supplier or engineer which national wind rules apply.

How wind acts on a pergola

Wind does not just push from the side. With a pergola, several effects occur at the same time:

  • Pressure on the windward side, for example on screens or glass walls.
  • Suction on the leeward side and on the roof. Over a flat roof, negative pressure develops that tries to lift the structure.
  • Gusts with short peaks that load components abruptly.
  • Channelling between buildings or along house walls, which locally raises wind speed.

For a louvred pergola this means: besides posts and beams, the anchorages in the foundation must also take tensile forces. In a storm a pergola can not only tip over but also lift off if the foundations are too light.

The wind zones in Germany

Wind zone Basic wind velocity vb,0 Basic velocity pressure qb,0 Rough guide
1 22.5 m/s 0.32 kN/m² Inland southern Germany
2 25.0 m/s 0.39 kN/m² large parts of central and northern Germany
3 27.5 m/s 0.47 kN/m² near-coastal areas, some exposed regions
4 30.0 m/s 0.56 kN/m² coast and islands of the North and Baltic Seas

The values refer to a wind speed averaged over ten minutes at 10 m height, exceeded with an annual probability of 2 per cent. Which zone applies to your municipality is shown by the DIBt assignment table.

Pergola wind load: when a location counts as exposed

The wind zone is only the starting value. Within a zone, the actual loading varies greatly. The following mainly count as exposed:

  • Coastal sites with open wind from the water,
  • hilltops, slopes and terrain edges where the wind accelerates,
  • open fields with no sheltering buildings or trees,
  • roof terraces and high balconies, because wind speed increases with height,
  • passages and corners between buildings.

In such locations a standard design is often not enough. A structural engineer takes terrain category and topography into account in the calculation.

Side elements change everything

An open pergola lets the wind largely through. As soon as you close sides, the exposed area rises considerably:

Side element Influence on wind load In practice
None small exposed area roof and suction are decisive
Zip screen large area, limited wind resistance retract in a storm, ideally by sensor
Sliding glass wall large, rigid area must be included in the pergola's structural design
House wall on one side wind shelter, but possible suction peaks wall connection must take tensile forces

For textile sun protection, the German roller shutter and sun protection trade association (Fachverband Rollladen + Sonnenschutz) cites wind resistance classes with test pressures from 75 N/m² (class 1) to 600 N/m² (class 6). For comparison, it recommends retracting conservatory awnings from about 12 m/s. Screens are more robust than loose awning fabric, but they too have a limit stated by the manufacturer. More in the article Zip screens on the pergola.

Wind sensors: automation as protection

Motorised pergolas can be coupled with wind sensors. Somfy describes the function like this: if wind speed exceeds a set value, the system moves to its protective position. There are sensors that measure wind speed with an anemometer, such as the Eolis, and variants such as the Eolis 3D WireFree io, which detect movement directly on the component.

Important points when setting up:

  • The threshold must match the wind resistance of the weakest component, usually the screens.
  • The sensor should stand freely in the wind and not in the lee of the house wall.
  • In a power cut the automation does not work. If you are away for a long time, retract screens as a precaution when a storm warning is issued.

How sensors and controls work together is explained in the article Rain and wind sensors for the pergola.

Foundations and anchoring

With high wind loads the foundation is the critical point. Pad foundations must be heavy enough to resist suction and deep enough to be founded below frost depth – at least 80 cm under DIN 1054. On an existing terrace slab, anchoring is sufficient only if slab and sub-base safely take the forces. Details are in the article Foundation for the pergola.

Example: the same pergola, two locations

Take a louvred pergola of 5 m × 4 m, 2.70 m post height and zip screens on two sides.

Location A: terraced-house garden in a small town in southern Germany, wind zone 1, surrounded by houses and hedges. The wind is slowed by the buildings. The screens retract automatically only rarely, and the system's standard design is generally sufficient.

Location B: detached house near the sea dyke on the North Sea, wind zone 4, open airflow across meadows. Here the basic velocity pressure is almost twice as high as in zone 1 – and because of the open setting the wind acts unchecked. The screens will often have to retract, the foundations are larger, and an additional post may make sense.

The pergola looks the same in both places. Structure, anchoring and operation differ markedly, however. That is why the location always belongs in the enquiry.

Tips for windy locations

  1. Assess wind zone and location honestly: always treat coast, hilltop or roof terrace as exposed.
  2. Choose a sheltered position: a pergola on the lee side of the house is less loaded.
  3. Reduce spans: shorter bays and additional posts increase stiffness.
  4. Plan screens with a sensor: only with automatic retraction do textile side elements make sense in exposed locations.
  5. Glass walls only with structural design: rigid side elements belong in the structural calculation.
  6. Check the wall connection: the fixing must take tensile and compressive forces.
  7. Follow the operating instructions: the manufacturer specifies the louvre position in a storm.

State of the art and limits of manufacturers' figures

Many manufacturers advertise wind resistance in km/h. Renson quotes, for example, "wind resistant up to 160 km/h" for its louvred roofs. Such statements are useful but only part of the truth: they apply to the system in question, particular dimensions and professional installation. They do not replace the site-specific calculation that takes wind zone, terrain and height into account. Always ask, therefore, which wind zone and terrain category a figure applies to.

Next step

Determine your wind zone and describe your site as precisely as possible in the enquiry – for example "near the coast, open location" or "roof terrace on the 4th floor". In the pergola configurator you plan dimensions, posts and side elements. For exposed locations we recommend consulting us through the contact form before ordering, so that design and foundations suit the site.

Frequently asked questions

Which wind zone applies at my location?

The DIBt provides an assignment of wind zones by administrative boundary. Germany is divided into wind zones 1 to 4; zone 4 mainly covers coasts and islands.

Can a louvred pergola withstand a storm?

That depends on the system and its design. Renson, for example, quotes wind resistance of up to 160 km/h for its louvred roofs – such values apply only to the system in question and correctly built foundations.

Do zip screens have to be retracted in a storm?

As a rule, yes. Textile screens have a limited wind resistance, which the manufacturer states. A wind sensor retracts them automatically when a set threshold is exceeded.

Should the louvres be open or closed in a storm?

The manufacturer specifies this in the operating instructions. Follow that guidance, because the system's wind load proofs are based on a particular position.

Sources

  1. DIBt: Technische Baubestimmungen und Zuordnung der Windzonen(opens in a new tab)
  2. DIBt: Windzonen nach Verwaltungsgrenzen (Tabelle)(opens in a new tab)
  3. Fachverband Rollladen + Sonnenschutz: Ermittlung der Windlasten (TR, April 2024)(opens in a new tab)
  4. Renson: Lamellendächer – Produktinformationen und FAQ(opens in a new tab)
  5. Somfy: Windsensor für Markise und Terrasse(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

Cover image: Pergola Structure: Span, Posts and Foundations
Pergolas & planning rules

Pergola Structure: Span, Posts and Foundations

Pergola structural design explained: how span, number of posts, snow and wind load and foundations are linked – and which structural proofs you need.

7 minutes read

Cover image: Pergola Foundation: Pad, Slab or Wall Mount?
Pergolas & planning rules

Pergola Foundation: Pad, Slab or Wall Mount?

Which foundation does your pergola need? Pad foundations, concrete slab or wall mounting compared – with frost depth, anchoring, drainage and a checklist.

6 minutes read

Cover image: Pergola Snow Load: Snow Load Zones Explained
Pergolas & planning rules

Pergola Snow Load: Snow Load Zones Explained

What snow load must a pergola carry? German snow load zones under DIN EN 1991-1-3/NA, formulas, conversion to kg/m² and worked examples for your louvred roof.

7 minutes read

We use strictly necessary cookies so the shop, configurator and basket work. With your consent we also use Google Analytics to measure how the site is used, and marketing signals for advertising. You can change your choice at any time in the footer. Read our privacy policy