Accessible Front Door: Thresholds, Clear Widths and Door Operators to DIN 18040-2
8 minutes read
An accessible front door to the German standard DIN 18040-2 has a clear passage width of at least 90 cm, a clear height of at least 205 cm and ideally no threshold; where a threshold is technically unavoidable, it may be no more than 2 cm high. Add easy operation, handles that are easy to grip at a height of 85 cm and enough manoeuvring space in front of the door. Where the door is too heavy, an automatic operator helps. The standard and funding described here apply to Germany; elsewhere, check your national accessibility rules (in the UK, for example, the building regulations).
Accessible Front Door: The Requirements of DIN 18040-2
DIN 18040-2 governs barrier-free building of dwellings and applies to residential buildings where the state building code introduces it or it is agreed by contract. Even where it is not compulsory, it is the recognised yardstick if you want to plan your entrance to be future-proof.
| Requirement | Value under DIN 18040-2 |
|---|---|
| Clear passage width | at least 90 cm |
| Clear passage height | at least 205 cm |
| Lower door stops and thresholds | not provided for; if technically unavoidable, max. 2 cm |
| Height of handles and controls | 85 cm (in justified cases 85–105 cm) |
| Operating forces | class 3 to DIN EN 12217 (opening force max. 25 N) |
| Manoeuvring space in front of swing doors | 150 × 150 cm |
| Distance to building elements beside the main closing edge | at least 50 cm |
The wheelchair-accessible version ("R" standard) in some respects sets higher requirements, for example for manoeuvring space. Whether your building project must be barrier-free under state law is clarified by the local building authority; this article does not replace legal advice.
Understanding Passage Width Correctly
The 90 cm is the clear width, meaning the passage actually free with the door open. Frame, hinges and the opened leaf itself reduce the dimension. A door whose outer frame measures 100 cm on the outside therefore does not necessarily reach this value. When buying, make sure the manufacturer states the clear passage dimension, and where wall openings are narrow, plan to widen them if necessary. How to measure correctly is shown in the article on front door dimensions.
Tip: a door that opens well beyond 90 degrees makes better use of the width. Check whether walls or radiators in the hallway limit the opening angle.
Threshold: Combining Weather Tightness and Accessibility
The threshold is the crux of every accessible front door. On the one hand it must not obstruct wheelchairs, walkers and pushchairs; on the other it must keep out wind, driving rain and draughts. Common solutions:
- Low aluminium thresholds with a maximum height of 2 cm and bevelled edges.
- Magnetic double seals: a magnet in the leaf pulls a seal up out of the threshold as soon as the door closes. This gives a zero threshold with a good sealing effect.
- Drop-down bottom seals: a seal in the leaf lowers onto the floor as the door closes.
- Drainage channel in front of the door and a canopy so that water does not collect in front of the low threshold.
The conflict of aims is covered in detail in the article on door thresholds on front doors.
Easy Operation: Handles, Forces, Locks
- Lever instead of knob: under DIN 18040-2, curved or U-shaped handles are well suited. A knob is hard to operate with limited hand strength.
- Operating forces: the standard calls for doors with low operating forces. A heavy leaf with a door closer quickly exceeds these; an operator then makes sense.
- Keyless opening: fingerprint, transponder or app save fiddling with the key. Which access media are suitable depends on the users' motor abilities.
- Automatic locking with motorised unlocking: opens the door fully at the press of a button, without bolts having to be turned back by hand.
Automatic Door Operators
For wheelchair users or people with walking aids, a swing door operator is often the decisive relief. It opens and closes the door by push button, radio transmitter, fingerprint reader or motion sensor. When planning, bear in mind:
- Power connection at the lintel and a cable transfer to the leaf.
- Combination with a motor lock, so that the door does not merely swing open but is unlocked beforehand.
- Safety sensors that stop the leaf if people are in the swing area.
- Manoeuvring space: under DIN 18040-2, larger areas must be allowed for in front of automatic doors with a frontal approach.
- Burglar resistance: the operator must be compatible with the tested specification of the door.
The Entrance Area as a Whole
Accessibility does not end at the door. DIN 18040 requires access and entrance areas to be easy to find and reachable without steps. That includes:
- a step-free path or a ramp,
- weather protection above the door,
- good lighting and high-contrast design,
- bell, entry phone and letterbox reachable without barriers,
- a clearly legible, high-contrast house number.
A canopy plays a double role here: it protects users while they unlock the door and reduces driving rain at the low threshold; see canopies and entrance areas.
Retrofit Instead of Buying New?
Not every existing front door has to be replaced for greater accessibility. Individual measures often help:
- Replace the threshold: with some door systems a high threshold can be swapped for a flatter profile, depending on the manufacturer and frame.
- Ramp wedges: mobile or fixed wedges bridge a few centimetres of height difference. They do not replace a solution that meets the standard, though.
- Lever instead of knob: swapping a handle set is quickly done.
- Retrofit operator: swing door operators can be fitted to many existing doors, provided leaf weight and frame are suitable.
If the door is too narrow, however, the only option is replacement with a widening of the opening.
Orientation for People with Visual Impairment
Contrasts help in finding the entrance: a door that stands out in colour from the wall, a handle that stands out from the door and a well-lit house number. For fully glazed doors, DIN 18040 calls for safety markings in two height ranges (40 to 70 cm and 120 to 160 cm).
Funding and Financing (as at September 2026)
- KfW loan 159 "Altersgerecht Umbauen": finances barrier-reduction measures with up to 50,000 euros per dwelling. The KfW technical minimum requirements specify for entrance doors a passage width of at least 90 cm and thresholds of no more than 20 mm where a threshold-free design is not structurally possible. The application is made through your own bank before the project starts.
- KfW grant 455-B: was reopened on 8 April 2026 with 50 million euros, and the funds were exhausted by 30 July 2026. Whether new funds will be available in 2027 is open.
- Care insurance fund: where a care grade has been awarded, home-adaptation measures such as door widening or removing thresholds can be subsidised with up to 4,180 euros per measure. The application should be made before work starts.
- Energy funding: if the door is also being replaced for energy reasons, the BEG grant or § 35c EStG come into consideration; see front door grants.
Checklist: Planning an Accessible Front Door
- Clear passage width ≥ 90 cm, clear height ≥ 205 cm
- No threshold or a maximum of 2 cm with bevelled edges
- Sealing concept and drainage in front of the door planned
- Lever handle at 85 cm height, easy operation
- Manoeuvring space of 150 × 150 cm in front of the door
- Operator, motor lock and power connection provided for
- Funding applications made before the order is placed
Choose a model with a suitable threshold among the front doors and put together width, opening direction and specification in the configurator.
Frequently asked questions
How wide must an accessible front door be?
Under DIN 18040-2, a clear passage width of at least 90 cm and a clear height of at least 205 cm are required. What is measured is the dimension actually usable with the door open, not the structural opening size.
How high may the threshold of an accessible front door be?
DIN 18040-2 provides for no lower door stops or thresholds. Where they are technically unavoidable, they may be no more than 2 cm high.
Is there funding for an accessible front door?
The KfW loan 159 finances barrier reduction with up to 50,000 euros per dwelling. The 455-B grant was open only briefly in 2026 and is exhausted. With a care grade, the care insurance fund may contribute up to 4,180 euros per measure (as at September 2026).
Do I need an automatic door operator?
Not necessarily. DIN 18040-2 calls for low operating forces. If a door is too heavy for that, for example because of a door closer, an automatic operator is the solution. For wheelchair users it is almost always a great relief.
Sources
- nullbarriere.de – DIN 18040-2 Türen(opens in a new tab)
- nullbarriere.de – DIN 18040-2 Bewegungsflächen(opens in a new tab)
- din18040.de – Eingang, Türen, Fenster(opens in a new tab)
- KfW – Technische Mindestanforderungen Altersgerecht Umbauen (159)(opens in a new tab)
- Energie-Fachberater – KfW-Zuschüsse Barrierefreiheit 2026(opens in a new tab)
- Deutscher Pflegebeistand – Wohnumfeldverbessernde Maßnahmen(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.