Front Door Sizes: Standard Dimensions, Measuring Up and Custom Sizes
7 minutes read
Unlike internal doors, front doors have no universally used standard sizes: they are normally made to measure. Typical door leaves are about 80 to 110 cm wide and around 200 to 210 cm high. What matters for the order is the exact size of the wall opening, measured in several places, plus the position of the finished floor. The sizes and standards quoted here are the German ones, which are metric; in other countries, local conventions for door sizes may differ.
Front Door Sizes: The Key Terms
When you compare quotes, you come across various dimension descriptions. They describe different things:
| Term | Meaning |
|---|---|
| Modular size (Baurichtmaß) | planning and grid dimension to DIN 18100, matched to the 12.5 cm masonry grid |
| Structural opening size (wall opening) | actual opening in the masonry; under DIN 18100 normally the modular size plus 1 cm joint |
| Outer frame dimension | outside dimension of the door frame, i.e. the order size of the door |
| Clear passage size | free passage with the door open |
| Installation joint | gap between frame and masonry for fixing and sealing |
DIN 18100 and DIN 18101 come mainly from the internal door sector. For front doors they are a guide for structural planning but do not determine the size of the door. Manufacturers almost always make front doors to the millimetre to the stated outer frame dimension.
Typical Widths and Heights
Guides give usual front door widths of about 80 to 110 cm and heights of about 200 to 210 cm. The manufacturing ranges of the systems differ by material. The Aroundhome portal gives this example:
- uPVC: about 76 to 126 cm wide and 188.5 to 238.5 cm high
- Timber: about 85 to 125 cm wide and 180 to 240 cm high
- Aluminium: about 70 to 125 cm wide and 170 to 240 cm high
These ranges are guide values; the actual limits depend on the profile system, the infill and the resistance class. A burglar-resistant door, for example, is certified only in the sizes that have been tested or are covered by the test certificate.
Minimum Dimensions for Accessibility
If the entrance is to be accessible under DIN 18040-2, the door needs a clear passage width of at least 90 cm and a clear height of at least 205 cm. Because frame and leaf take up space, the structural opening has to be considerably larger for this. More in the article on accessible front doors.
Measuring a Front Door Properly: Step by Step
For a replacement, you measure the existing opening. The survey is most accurate once the old door has been removed; in practice measurements are usually taken beforehand, allowing for the plaster and frame area.
- Measure the width: at the top, in the middle and at the bottom between the reveals. The smallest figure is the one that counts.
- Measure the height: on the left, in the middle and on the right from the structural bottom edge to the lintel. Here too the smallest figure counts.
- Check the diagonals: if the diagonals differ markedly, the opening is not square, and this has to be allowed for in the joint.
- Establish the floor build-up: where is the finished floor inside and outside? Is a new covering, a step or a landing coming? This determines the position of the threshold.
- Deduct the installation joints: joints for fixing, insulation and sealing are deducted all round from the structural size. The joint width depends on the fitting system.
- Clarify the reveal detail: does the door sit in a masonry rebate or butt against the reveal? Is it fitted in the insulation plane?
The basic principle is the same as for measuring windows, which is described in detail in the article on measuring windows correctly. With front doors, the threshold adds a further source of error.
The Most Common Measuring Errors
- Measured in one place only: wall openings are seldom exactly straight.
- Took the old frame as the reference: its dimension does not match the structural opening size.
- Forgot the floor height: the door drags or the threshold stands too high.
- Did not allow for external insulation: if façade insulation is added later, the door should often sit further out.
- Confused order size with passage: depending on the profile system, the clear size is smaller than the outer frame dimension by the frame and leaf sightlines. As a rule of thumb for the wall opening, Aroundhome gives the desired passage width plus about 8 cm and passage height plus about 4 cm.
Custom Sizes and Special Shapes
Since front doors are mostly made to measure, widths and heights that depart from the norm within the system range are normal. Genuine special cases are:
- Extra-wide and extra-tall doors beyond the system limits of the chosen model
- Round-arch and segmental-arch doors, especially in older buildings; see front doors in older buildings
- Sloping fanlights at gables or in stairwells
- Units with sidelights and fanlight, in which the overall width is divided among several elements
According to Aroundhome, you should expect longer delivery times for custom sizes; the actual lead time depends on the manufacturer.
Sidelight Instead of Extra Width
If the opening is very wide, a normal door plus a sidelight often makes more sense than an extra-wide leaf. This keeps the leaf weight reasonable, spares the hinges and provides room for letterbox and bell. Planning tips can be found in the article on front doors with sidelight and fanlight.
Enlarging or Reducing the Opening
If the existing opening does not suit the door you want, there are two routes:
- Reducing: with packing, widening profiles or masonry infill. This is usually straightforward.
- Enlarging: requires cutting back the reveal and, for wider openings, a new lintel. This is an intervention in the load-bearing structure and should be structurally designed. Alterations to the façade may also be subject to planning law; if in doubt, clarify this with the building authority.
Fixing Dimensions in a New Build
In a new build, the architect or builder plans the opening. Agree the door size early with the structural planning, because the opening can later be changed only with effort. Important points are:
- Position of the door in the wall: with insulated external walls, the door ideally sits in the insulation plane.
- Connection to the floor slab: threshold, damp-proofing and floor build-up must fit together.
- Canopy and external steps: these affect the threshold height and hence the door height.
- Accessibility: if you want to live without thresholds later, plan the passage width generously from the start.
Record all dimensions in writing and photograph the opening from inside and outside. Photos help to place special features such as steps, cables or protruding window sills later. It is best to note the values on a sketch showing the inside, the outside and the opening direction.
Checklist for the Survey
- Width measured at top, middle and bottom, smallest figure noted
- Height measured left, middle and right, smallest figure noted
- Diagonals compared
- Finished floor inside and outside established
- Installation joints deducted according to the fitting system
- Clear passage size checked if accessibility is wanted
- Opening direction and hand noted
With your dimensions you can put together the front door to measure in the configurator. If you are unsure whether your survey is right, get in touch beforehand via the contact page.
Frequently asked questions
Are there standard sizes for front doors?
Unlike internal doors, front doors have no universally used standard sizes. Most front doors are made to measure. Usual door leaves are roughly between 80 and 110 cm wide and around 200 to 210 cm high.
What is the difference between structural opening size and clear size?
The structural opening size describes the wall opening into which the door is fitted. The clear size is the free passage with the door open, and it is considerably smaller because frame and leaf take up space.
How do I measure my front door correctly?
Measure the width and height of the wall opening in at least three places each and use the smallest figure. Also establish where the finished floor level is inside and outside. If you are claiming a grant, or are unsure, a specialist firm should take the measurements.
Do custom sizes cost more for front doors?
Since front doors are usually made to measure anyway, widths or heights that depart from the norm within the system range often cost little extra. Surcharges arise mainly for extra-wide or extra-tall doors and special shapes such as round arches.
Sources
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.