HST schemes A, C, G and K: which lift-and-slide door configuration suits your wall opening?
6 minutes read
The HST scheme describes how the glazed front of a lift-and-slide door is divided: how many panels there are, which of them slide and which are fixed. The main variants are scheme A (one sliding sash plus one fixed panel), scheme C (two central sliding sashes between two fixed panels), scheme D (two sliding sashes) and the three-part schemes G and K. Choosing the right scheme also determines the passage width, the furniture layout and the price.
Why schemes exist at all
The letters come from hardware technology. Each configuration needs different gearboxes, carriages, threshold profiles and mullions. So that window fabricators, profile makers and hardware manufacturers all mean the same thing, shorthand codes have become established. Profile systems state which schemes they support: the Aluplast HST 85 uPVC system, for instance, supports schemes A, C, D and F, while Alumat's HST 20 low threshold is compatible with A, C, D, F, G and K, among others.
What matters for you as the client: the basic forms are largely standardised, but for rarer variants manufacturers sometimes use their own sub-types such as G2 or G3. So never rely on the letter alone; always rely on the drawing in your quotation. How the lift-and-slide mechanism works in principle is covered in our basic article on the lift-and-slide door.
The common HST schemes compared
| Scheme | Panels | Layout | Typical use |
|---|---|---|---|
| A | 2 | 1 sliding sash, 1 fixed panel | Standard patio door, openings up to medium width |
| D | 2 | 2 sliding sashes on two levels | When you want to open to either the left or the right |
| C | 4 | 2 sliding sashes in the centre, 2 fixed panels at the sides | Very wide fronts with a large central opening |
| F | 4 | 4 sliding sashes | Maximum flexibility on wide fronts |
| G | 3 | Sliding sash and fixed panels, symmetrical or asymmetrical (manufacturer-dependent) | Three-part fronts with a central opening |
| K | 3 | Fixed panel in the centre, 2 sliding sashes at the sides | Two separate passages, e.g. to terrace and garden |
| E | 3 | 3 tracks, sliding sashes stack behind a fixed panel | Large open proportions with three-track frames |
Scheme A: the basic form
Scheme A is by far the most common. One sliding sash runs in front of or behind a fixed panel. About half of the element width is opened. Its advantages: only one set of hardware, the lowest price and simple operation. When ordering, you specify whether the sliding sash sits on the left or right and which way it opens.
Planning tip: do not place tall furniture in front of the fixed panel if the sliding sash runs inside in front of it, otherwise the sash will collide when opening.
Scheme C: a large central opening
Scheme C has four panels: two fixed panels at the outside and two sliding sashes in the middle that run apart to the left and right. This creates a wide opening in the centre of the front, ideal for living rooms with a central terrace axis. Hardware manufacturers usually specify a fixed order for scheme C: the first sash is opened first, then the second; when closing, the reverse.
Scheme D: two sliding sashes without a fixed panel
In scheme D both panels move and run on two levels. They can open to either the left or the right, which is handy if the access point needs to change depending on use. Because two sets of hardware are needed, the price is higher than for scheme A.
Three-part variants: schemes G and K
Three-part fronts are popular when the wall opening looks too wide for two panels or when a symmetrical look is wanted.
- Scheme K: the fixed panel is in the middle, with one sliding sash to the left and one to the right. This gives two separate passages, for example one to the dining area and one to the living area.
- Scheme G: manufacturers use this for three-part arrangements with a sliding sash and fixed panels, symmetrical or asymmetrical. Depending on the manufacturer there are sub-variants (G2, G3) that differ in the number and position of the sliding sashes.
With G in particular, it pays to look closely at the drawing: which panels move, in which direction do they run, and where are the fixed panels?
Scheme E and other special forms
Besides the basic forms there are variants for special requirements. With scheme E the frame has three tracks: a fixed panel sits on one level, and two sliding sashes run on their own tracks and can be pushed one behind the other in front of the fixed panel. This frees up a larger share of the front than two-track solutions. For its classic lift-and-slide systems, Schüco describes installations with up to three tracks. Even wider installations combine six or more panels; such solutions are usually planned individually.
The more tracks, the deeper the frame and the wider the threshold. That affects the connection to floor and wall as well as the options for a near step-free transition.
Scheme, passage width and price
Element width is not the same as passage width. With scheme A the sliding sash frees up slightly less than half of the element width, because the sash frame, the overlap with the fixed panel and the handle all need space. With scheme C the openings of both central sashes add up, while with scheme K two smaller openings arise to the left and right. If you need a particular clear width, for example 90 cm for an accessible passage, base the scheme on that and check the dimensions in the quotation drawing.
For price, a simple rule of thumb applies: every additional sliding sash brings another set of hardware with gearbox, carriages and locking. Scheme A is therefore the cheapest variant, with schemes D, C, K and F above it. Fixed panels are comparatively inexpensive because they are only glazed, not movable.
Which scheme suits your project?
Answer these questions before you configure:
- How wide is the opening? Up to about three metres, scheme A is often enough; for much wider fronts, three- or four-part schemes come into play.
- Where should people walk through? In the centre (C), at the side (A) or in two places (K)?
- How will the room be furnished? In front of fixed panels there is space for furniture; in front of running sashes there is not.
- How heavy will the sashes be? Very wide sashes with triple glazing quickly reach high weights. The glass thickness and structural design of large areas limit the sensible sash width.
- Will a drive follow? Retrofit and built-in drives are often designed for particular schemes. Siegenia, for instance, specifies schemes A and C for its DRIVE axxent HSA smart and MHS400 smart drives. More in our article on the lift-and-slide door with motor drive.
- Which threshold? Multi-track schemes need wider thresholds; for step-free solutions the chosen threshold has to suit the scheme.
Typical ordering mistakes
- Sliding direction mixed up: check whether the drawing shows the view from inside or outside.
- Fixed panel on the wrong side: think about radiators, sockets and light switches beside the opening.
- Scheme does not suit the profile: not every system offers every scheme; during configuration only permissible variants are offered.
- Forgetting the insect screen: the layout determines where an insect screen for the sliding door can run.
Next step: decide the scheme and configure
Measure your opening, sketch furniture and walking routes, and then decide on the scheme. In the online configurator you choose the layout directly, see the drawing and get an instant price. You will find an overview of all variants and materials on the lift-and-slide doors page. Are you a window fitter or developer? Then a B2B account with tiered pricing for repeat projects is worthwhile.
Frequently asked questions
What does scheme A mean for a lift-and-slide door?
Scheme A is the basic two-part form: one sliding sash and one fixed panel. The sliding sash runs in front of or behind the fixed panel and frees up roughly half of the element width as a passage.
Which HST scheme gives the largest opening?
Variants with several sliding sashes, such as scheme D (two sliding sashes) or scheme F (four sliding sashes), free up the largest proportion. Scheme C, with two central sliding sashes, allows a wide central opening on very large overall widths.
Are the scheme letters the same for all manufacturers?
The basic forms A, C and D are used fairly consistently. For three-part variants such as G and K, and for sub-types such as G2 or G3, manufacturers differ. The drawing in your quotation is always what counts.
Do I need to state the sliding direction as seen from inside or outside?
That depends on how the manufacturer draws it. Check in the quotation drawing whether the view is shown from inside or outside before you confirm left or right as the sliding direction.
Sources
- Aluplast HST 85 mm Hebe-Schiebe-System – verfügbare Schemata A, C, D, F(opens in a new tab)
- ALUMAT Einbaurichtlinie HST 20 Flachschwelle (Schema D, A, C, F, G, K)(opens in a new tab)
- SIEGENIA DRIVE axxent HSA smart – Antrieb für Schema A und C(opens in a new tab)
- SIEGENIA MHS400 smart – Nachrüstantrieb für Schema A und C(opens in a new tab)
- Schüco Schiebetüren – Klassik Design mit bis zu drei Laufschienen(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.