Sliding door security: how to protect lift-and-slide and tilt-and-slide doors effectively
6 minutes read
With sliding door security, it is the interplay that counts: frame, hardware, glass and installation must be tested together. For new builds and conversions, the German police recommend windows and doors to DIN EN 1627 from resistance class RC 2. Existing patio doors can be improved with tested retrofit products to DIN 18104, whereas burglar-resistant glass alone is not enough. The police advice and statistics cited here are German; in the UK, the equivalent standard is PAS 24 / Secured by Design, so check which applies to you.
Why patio doors are a favoured target
Patio and balcony doors are often on the garden side, are poorly visible from the street and offer large surfaces. The police initiative K-EINBRUCH points out that an inadequately secured window can be levered open with simple tools in a few seconds. At the same time, the figures show that security technology is worthwhile: according to the German police crime statistics, a total of 82,920 residential burglaries, including attempts, were recorded in 2025; 44.9 per cent remained attempts, often because the offenders were defeated by the security technology.
What RC 2 to DIN EN 1627 means
The European standard DIN EN 1627 classifies burglar-resistant windows, doors and closures into resistance classes from RC 1 N to RC 6. The higher the class, the more tools and time an offender needs. For residential buildings RC 2 has become the standard. There is also RC 2 N, which can be met with standard window glass. For easily reached elements such as ground-floor patio doors, RC 2 with burglar-resistant glass is the sensible choice.
| Class | Short description | Typical use |
|---|---|---|
| RC 1 N | basic protection, hardly any burglar resistance | hard-to-reach elements |
| RC 2 N | like RC 2, but without burglar-resistant glass | elements where the glass is not easily reached |
| RC 2 | tested unit including burglar-resistant glazing | ground floor, patio and balcony doors |
| RC 3 | longer resistance time, heavier tools | higher risk, commercial |
The differences between RC 2 and RC 2 N are explained in the article RC 2 or RC 2 N.
Important: a resistance class always applies to the tested complete unit. Manufacturers test specific combinations of profile, hardware, glass and fixing. If one component differs or is installed incorrectly, the class no longer applies.
The weak points of a sliding door
Levering the sash
The most common attack: a tool is placed between sash and frame and the sash is forced open. Burglar-resistant hardware uses several locking points with security keeps. For the PORTAL HS 150 kg lift-and-slide hardware, Siegenia states burglar resistance up to RC 2, achieved via a gearbox with bolt locking.
Lifting a lift-and-slide door out
Because the sash of an HST can be lifted, manufacturers test in particular whether it can be levered out from outside. Anti-lift-out devices in the top frame and sturdy tracks prevent this.
Glass
Standard insulating glass can be smashed. Burglar-resistant laminated safety glass is classified to DIN EN 356: classes P1A to P5A describe resistance to being thrown through, and P6B to P8B to breaking through. K-EINBRUCH gives laminated safety glass from class P4A for vulnerable windows.
Handle
A lockable handle prevents the door simply being opened from inside after a small opening has been smashed. More in the article on lockable window handles.
Installation
The best door is of no use if it is held in the masonry only with foam. For RC-tested elements the manufacturer specifies fixing distances and fixings, which must be observed.
A new sliding door with RC 2
When buying a new lift-and-slide or PSK door, ask specifically for a tested resistance class. Many profile systems offer RC 2; Schüco, for instance, quotes burglar resistance up to RC 2 for its ASE 60 and ASE 80.HI aluminium lift-and-slide systems and for the LivIngSlide uPVC system, and up to RC 3 for the AS PD 75.HI panoramic system.
Look for:
- A test certificate or declaration of performance stating the resistance class
- Burglar-resistant glass of the required class
- A lockable handle on the inside
- An installation certificate confirming installation in line with the manufacturer's specification
Upgrading an existing sliding door
For existing doors, the police recommend retrofit systems to DIN 18104 Part 1 (surface-mounted retrofit products) and Part 2 (retrofit products fitted in the rebate). Options for sliding doors include:
- Additional locks on the sash that connect frame and sash
- Espagnolette bolts with locking at top and bottom
- Lockable handles
- Anti-lift-out devices in the upper area
- Security film or replacing the glass, only in combination with mechanical security
The police stress that security devices only achieve their full effect if professionally fitted. Free advice is available from the (criminal) police advice centres. Further retrofit options are described in the article retrofitting burglar protection.
Typical misconceptions about burglar protection
- "Triple glazing is burglar-proof." More panes do not mean more burglar protection. What matters is a tested laminated safety glass pane with a P classification.
- "A lockable handle is enough." The handle only prevents opening from inside after the glass is broken. It does not help against levering.
- "Security hardware equals RC 2." Only the tested complete unit receives a resistance class.
- "Lift-and-slide doors are easy to lift out." Modern, tested systems have anti-lift-out devices. Older doors without such devices should be retrofitted.
- "An alarm system replaces mechanical security." An alarm reports the burglary but does not prevent it. The police see mechanical security as the foundation.
Costs and funding
Burglar-resistant specification costs extra: for hardware, glass, handle and often a more elaborate installation. The extra cost depends heavily on size and system. For energy funding, it is worth knowing that under the technical minimum requirements for BEG individual measures, burglar-resistant windows and doors may have a slightly higher Uw value than standard windows. Your energy efficiency expert will give you the currently valid values. Whether there are grants for burglar protection as well depends on the individual funding programmes; check the current conditions with KfW and your federal state. These funding rules are German; readers elsewhere should check local schemes.
Complementary measures
- Roller shutters provide extra protection if they are fitted with lift-up locks. K-EINBRUCH advises closing roller shutters at night but not during the day, so as not to signal absence.
- Lighting with a motion sensor on the garden side.
- Alarm systems supplement mechanical security but do not replace it.
Special considerations for upper-floor balcony doors
Burglars do not only enter at ground level. Balconies, flat roofs of garages or conservatories, bins and climbing frames can make access to the upper floor easier. Check whether a sliding door on the first floor is really hard to reach. If it can be reached via extensions or climbing aids, the same recommendations apply as for the ground floor. If it really is hard to reach, RC 2 N, the version without burglar-resistant glass, can be a sensible, cheaper choice.
Checklist
- New door: choose resistance class RC 2 with burglar-resistant glass
- Request proof of the resistance class for the complete unit
- Specify a lockable handle
- Have installation carried out exactly to the manufacturer's specification
- Existing door: have retrofit products to DIN 18104 professionally installed
- Use the police advice service
For our lift-and-slide doors, you select the security specification directly in the configurator, including hardware, glass and lockable handle.
Frequently asked questions
Which resistance class do the police recommend for patio doors?
The German police crime-prevention service recommends tested burglar-resistant windows and doors to DIN EN 1627, from resistance class RC 2, for new builds and conversions.
Is burglar-resistant glass enough on its own?
No. According to the K-EINBRUCH advice, windows and doors are frequently levered open, so upgrading with burglar-resistant glass alone is not enough. Frame, hardware, glazing and installation must work together.
Can an existing sliding door be upgraded?
Yes, with tested retrofit products. The police recommend systems to DIN 18104 Parts 1 and 2, professionally fitted. Which products suit your sliding door depends on the profile and the hardware.
Does RC 2 apply if only the hardware is RC 2?
No. The resistance class applies to the tested complete unit of profile, hardware, glass and fixing. RC 2-capable hardware is a prerequisite but does not on its own make an RC 2 door.
Sources
- Polizeiliche Kriminalprävention – Technische Sicherheit(opens in a new tab)
- K-EINBRUCH – Sicherheitstipps Fenster und Terrassentüren(opens in a new tab)
- K-EINBRUCH – Startseite mit Fallzahlen aus der PKS(opens in a new tab)
- Einbruchhemmung – Wikipedia (DIN EN 1627)(opens in a new tab)
- SIEGENIA PORTAL HS 150 kg – Einbruchhemmung bis RC 2(opens in a new tab)
- BF-Merkblatt 013 – VSG im Bauwesen(opens in a new tab)
- Schüco Schiebetüren – Einbruchhemmung der Systeme(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.