Summer heat protection ensures that rooms behind large windows do not overheat in summer. The most effective measure is external, movable solar shading such as raffstores, roller shutters or awnings; added to that come suitable window sizes, glass with an appropriate g-value, thermal mass and targeted night ventilation. For new buildings in Germany, the proof to DIN 4108-2 is a legal requirement. UK and other readers should check their own overheating rules (in England, Approved Document O).

Why large glass areas become a problem in summer

Windows let solar energy in: a gain in winter, a burden in summer. Radiation passes through a glass area into the room, is absorbed by floor, furniture and walls and released again as heat. That heat cannot get back out through the pane. The larger the glass area relative to the size of the room and the more it faces south, west or east, the more the room heats up.

Particularly critical are:

  • West-facing windows: the sun is low in the afternoon and strikes the pane almost perpendicularly when the room is already warm.
  • Roof windows and glass roofs: high radiation at midday.
  • Lightweight construction: little thermal mass to buffer the heat.
  • Corner rooms with two glazed sides.

The German Environment Agency (UBA) stresses that, given climate change, individual measures are often no longer enough, and that external solar shading and intensive night ventilation are particularly effective.

What the law requires

Under section 14 of the Building Modernisation Act (GModG, known as the Building Energy Act until July 2026), a new building in Germany must be constructed so that solar gain is limited by adequate structural summer heat protection according to the recognised rules of technology. The relevant standard is DIN 4108-2, 2013-02 edition. Proof is provided either via the solar gain characteristic or via a thermal building simulation.

According to the GModG information portal, the proof for residential buildings can be dispensed with if both conditions are met (status: September 2026):

  1. In the critical room, the one with the highest solar radiation, the window area proportion relative to floor area is no more than 35 per cent.
  2. All east-, south- or west-facing windows have external solar shading devices with a reduction factor Fc ≤ 0.30.

For renovation of existing buildings there is no corresponding obligation to provide proof. It is still sensible to consider the issue, especially if windows are being enlarged. This article explains the principles and does not replace professional planning or legal advice.

The adjustable factors at a glance

Measure Effect Note
External solar shading (raffstore, roller shutter, awning, zip screen) very high stops radiation in front of the pane, adjustable
Solar control glass medium to high works permanently, also in winter
Internal solar shading (blind, roller blind) low the heat is already in the room
Structural shading (roof overhang, balcony, pergola) high for south windows less effective against low east and west sun
Window size and orientation fundamental fix early in planning
Thermal mass (solid walls, screed) buffering only effective in combination with night ventilation
Night ventilation high requires secure ventilation openings

The Fc value: a measure of effective shading

The reduction factor Fc states what proportion of solar energy still reaches the room despite solar shading. An Fc of 0.30 means that with shading only 30 per cent of what would fall in without protection gets in. In simplified terms, the effective energy transmittance is the g-value of the glass multiplied by Fc.

External solar shading achieves low Fc values because the radiation is intercepted before the pane. Internal solar shading lets the energy through the glass first and then holds it in the room, so its Fc value is considerably higher. The manufacturer will give the specific Fc values for your product; DIN 4108-2 contains guide values for typical systems.

Glass: choosing the g-value deliberately

The g-value of the glazing directly affects heat gain. Double-glazed thermal insulation glass is typically 0.6 to 0.72, triple-glazed thermal insulation glass 0.5 to 0.6, and special solar control glass roughly 0.27 to 0.48. Solar control glass makes sense where movable external protection is not possible. The pros and cons are explained in the article solar control glass for large window areas; the basics of the characteristic value are in g-value and light transmission.

Ventilation: getting rid of the heat again

Even with good solar shading, heat accumulates in the building during the day. At night, when it is cooler outside, this heat should be removed. That needs:

  • Openable sashes on different sides for cross ventilation
  • Burglar-safe ventilation positions, so windows can stay open at night
  • Skylights or roof windows, through which warm air rises out

A lift-and-slide door cannot be tilted. Plan a tiltable window alongside if the room is to be ventilated at night.

Thermal mass and room geometry

How quickly a room heats up also depends on how much heat walls, ceilings and floors can absorb. Solid elements of concrete, sand-lime brick or clay brick buffer temperature peaks; lightweight constructions with plasterboard, suspended ceilings and carpet react much faster. The UBA lists solid walls and ceilings and smaller window areas as building blocks against overheating. Thermal mass only helps, however, if the stored heat is removed again at night. Without night ventilation the room is already pre-warmed the next morning.

The ratio of glass area to room floor area also plays a role. This is exactly what the exemption rule in the GModG, with its 35 per cent window area proportion in the critical room, is aimed at. A small study with large west-facing glazing is much more at risk than a large living room with the same window area.

In practice: a west-facing glass front

A typical case: a living room with a large lift-and-slide door facing west. Recommended here:

  1. External raffstore or zip screen: adjustable, with a good Fc value, and with raffstores also directing daylight.
  2. Triple-glazed thermal insulation glass with a balanced g-value rather than dark solar control glass, so solar gains remain possible in winter.
  3. Automatic control with sun and wind sensor, so that the protection also works when you are away.
  4. A tilting window on the east side for cross ventilation at night.

Which external protection suits your window is compared in the article raffstore or roller shutter.

Common planning mistakes

  • Planning solar shading afterwards: a raffstore or roller shutter box needs space in the lintel or in front of the facade. If it is only planned after the windows are installed, often only a surface-mounted solution remains.
  • Relying on internal blinds alone: they protect against glare and views in but hardly keep out any heat.
  • Forgetting east windows: in the morning the sun shines at a low angle on east facades. Bedrooms on the east side heat up early.
  • Automatic control without a wind sensor: external solar shading must be retracted in storms. Without a sensor it either stays up when it is needed or gets damaged.
  • No secure night ventilation: if you close all windows at night for security reasons, you lose the most important source of cooling.

Funding

Under the BAFA individual measures for the building envelope in Germany, summer heat protection through the replacement or first-time installation of external solar shading devices with optimised daylight supply is eligible for funding (status: September 2026). Conditions and technical minimum requirements are clarified by the energy efficiency expert, who must be involved in the application. Funding rules elsewhere differ; check local schemes.

Checklist against overheating

  • Record orientation and size of all glass areas
  • Identify the critical room
  • Provide external solar shading for east, south and west windows
  • Choose the g-value of the glazing appropriately
  • Allow cross ventilation and night ventilation
  • Consider automatic control with sensors
  • For new builds: proof to DIN 4108-2 by the planner

You can configure our roller shutters and raffstores to match windows and sliding doors. On terraces, a bioclimatic pergola with rotating louvres also provides shade in front of the glass front.

Frequently asked questions

What does summer heat protection mean?

Summer heat protection covers all building measures that prevent rooms from heating up excessively in summer through solar radiation, above all solar shading, suitable window sizes, thermal mass and ventilation.

Is the proof to DIN 4108-2 mandatory?

For new buildings in Germany, yes: section 14 of the Building Modernisation Act requires adequate structural summer heat protection to DIN 4108-2. For residential buildings the proof can be dispensed with under certain conditions, such as a small window area proportion and external solar shading.

What is the Fc value?

The reduction factor Fc describes how much a solar shading device reduces the energy entering through the window. The smaller the value, the more effective the protection. External solar shading achieves considerably lower Fc values than internal.

Does triple glazing help against heat?

Somewhat, because triple glazing usually has a lower g-value than double glazing. But the real difference is made by external solar shading; triple glazing alone does not prevent overheating behind large south or west windows.

Sources

  1. § 14 GModG – Sommerlicher Wärmeschutz(opens in a new tab)
  2. GModG-Infoportal: Anforderungen an Wohngebäude (Neubau)(opens in a new tab)
  3. Umweltbundesamt – Energiesparende Gebäude(opens in a new tab)
  4. Gesamtenergiedurchlassgrad – Wikipedia(opens in a new tab)
  5. BAFA – Einzelmaßnahmen an der Gebäudehülle (sommerlicher Wärmeschutz)(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

Cover image: Solar Control Glass for Large Window Areas
Lift-and-slide doors

Solar Control Glass for Large Window Areas

Solar control glass for large windows: g-value, light transmission and selectivity explained, with example values, pros and cons and tips on choosing.

6 minutes read

Cover image: Corner Glazing and Frameless Glass Corners
Lift-and-slide doors

Corner Glazing and Frameless Glass Corners

Corner glazing and frameless glass corners: types, structure, insulation, condensation and costs explained, plus tips on corner windows and sliding doors.

6 minutes read

Cover image: Sliding Door Security: Securing Large Glass Doors
Lift-and-slide doors

Sliding Door Security: Securing Large Glass Doors

Burglar protection for sliding doors: what RC 2 to DIN EN 1627 means, which hardware and glass help and how to sensibly upgrade existing patio doors.

6 minutes read

We use strictly necessary cookies so the shop, configurator and basket work. With your consent we also use Google Analytics to measure how the site is used, and marketing signals for advertising. You can change your choice at any time in the footer. Read our privacy policy