The g-value of a window: how much solar energy your glass lets in, and why it matters
6 minutes read
The g-value of a window, officially the total solar energy transmittance, states what proportion of solar energy gets through the glass into the room. A g-value of 0.5 means that half of the incident energy comes in as heat. Typical values are 0.6 to 0.72 for double-glazed and 0.5 to 0.6 for triple-glazed thermal insulation glass, and 0.27 to 0.48 for solar control glass. Together with the U-value, the g-value decides whether a window loses or gains energy overall.
What the g-value actually measures
Solar radiation strikes the pane. Part of it is reflected, part absorbed by the glass, and part passes straight through. The absorbed part warms the glass, which releases some of the heat inwards. The g-value combines the direct transmission and this secondary release of heat inwards. It lies between 0 (nothing comes in) and 1 (everything comes in). The calculation is set out in DIN EN 410; guide values are in DIN 4108-4.
g-value, light transmission and selectivity
Three characteristic values describe how a glass deals with sunlight:
| Value | Meaning | Effect |
|---|---|---|
| g-value | proportion of total solar energy that comes in | heat gain or overheating |
| Light transmission (LT, τv) | proportion of visible light that passes through | brightness in the room |
| Selectivity | light transmission divided by g-value | light per heat |
The g-value does not allow a direct statement about brightness because it covers the whole spectrum including infrared. A good solar control glass lets through a lot of light but little heat, meaning it has high selectivity. An example from manufacturer data: Guardian SunGuard SN 70/35 has 70 per cent light transmission with a g-value of 35 per cent, so a selectivity of around 2.
Typical g-values at a glance
| Type of glass | g-value (typical) |
|---|---|
| Double-glazed thermal insulation glass, argon, one coating | 0.60–0.72 |
| Triple-glazed thermal insulation glass, argon, two coatings | 0.50–0.60 |
| Solar control glass | 0.27–0.48 |
The values are orders of magnitude from technical sources. The manufacturer gives the exact g-value of your glass in the quotation.
The window's energy balance
A window loses heat via the U-value and gains heat via the g-value. Which effect dominates depends on:
- Orientation: south windows receive the most sun in winter, north windows hardly any.
- Shading: neighbouring buildings, trees, balconies or roof overhangs reduce solar gains.
- Climate and location: sunny locations benefit more.
- Use: the heat also has to be needed in the room. In the transitional seasons it can lead to overheating.
Comparing double and triple glazing shows: triple glazing has a slightly lower g-value but loses considerably less heat. For most windows in Germany, the lower heat loss outweighs it. Details in the article double or triple glazing.
Choosing the g-value to suit the situation
South windows with external solar shading
Here the highest possible g-value is worthwhile. In winter a lot of free heat comes in, and in summer the solar shading keeps it out. Passive house designers deliberately choose triple glazing with a high g-value for large south-facing glazing.
West and east windows without solar shading
The low sun in the morning and afternoon heats rooms up strongly. Where no external protection is possible, a lower g-value can make sense. What solutions there are is described in the article summer heat protection.
Glass roofs and roof windows
High radiation in summer and difficult shading often favour solar control glass with a low g-value. Which glasses exist and what they mean in daily life is described in the article solar control glass for large window areas.
North windows
Here the g-value hardly matters; the low U-value is decisive.
Worked example: solar gain of a south window
A simplified example shows how strongly the g-value acts. Suppose 400 W/m² of solar radiation falls on a 2 m² south-facing window at midday on a clear winter day, so 800 W on the whole area.
- Double glazing with g = 0.65: around 520 W gets into the room.
- Triple glazing with g = 0.55: around 440 W gets into the room.
- Solar control glass with g = 0.35: around 280 W gets into the room.
At the same time the window loses heat via the U-value. At a 20 kelvin temperature difference, double glazing with Ug 1.1 loses about 44 W over 2 m², triple glazing with Ug 0.6 about 24 W. In the midday sun, both windows therefore gain considerably more than they lose. At night and on overcast days there is no solar gain, and only the U-value counts, where triple glazing is clearly ahead.
The figures are for illustration and take no account of frame proportion, angle of incidence or shading. For a reliable balance, an energy adviser calculates with climate data for your location.
The g-value in combination with frame and shading
The g-value applies to the glazing. The actual solar gain of a window is smaller because the frame lets no solar energy through. Slim profiles and large, undivided panes therefore increase the gain. Reveal depth, roof overhang and balconies also play a part: a window set deep in the wall is partly shaded by the reveal in summer, a welcome effect, but hardly at all in winter when the sun is low.
Legal framework
For new buildings in Germany, section 14 of the Building Modernisation Act requires adequate structural summer heat protection to DIN 4108-2. The g-value of the glazing feeds into the solar gain characteristic there, together with the reduction factor Fc of the solar shading. For residential buildings the proof can be dispensed with if, in the critical room, the window area proportion relative to floor area is at most 35 per cent and all east, south and west windows have external solar shading with Fc ≤ 0.30 (status: September 2026). For replacing windows in existing buildings there is no g-value requirement, but there are U-value requirements. Readers in the UK or elsewhere should check their own overheating and energy rules.
Where to find the g-value
The g-value is in the technical data sheet of the glazing, in the window's declaration of performance or in the quotation. Ask for it specifically if it is not stated, especially for large south- and west-facing glass areas.
Common misconceptions
- "A low g-value is always better." No: in winter you give away solar heat.
- "Dark glass is solar control glass." Not necessarily. Modern solar control glasses are often neutral and light.
- "The g-value is printed on the pane." Usually not; it is in the product documents.
- "Internal blinds lower the g-value." The g-value applies to the glass. Internal solar shading reduces heat gain only a little because the energy is already in the room.
Checklist
- Note the orientation of each window area
- Check external solar shading for east, south and west
- With good solar shading: prefer glass with a high g-value
- Without solar shading: consider a lower g-value or solar control glass
- Compare light transmission and selectivity
In the configurator you choose the glazing for your windows. If you need particular g-values, for example for a passive house or a glass roof, we are happy to prepare an individual quotation.
Frequently asked questions
What does the g-value tell you?
The g-value (total solar energy transmittance) states what proportion of the incident solar energy gets through the glass into the room, as direct radiation and as heat the glass releases inwards. It lies between 0 and 1.
Is a high or a low g-value better?
That depends on orientation and season. In winter a high g-value delivers free solar heat, in summer it can lead to overheating. For south windows with external solar shading, a high g-value is usually advantageous, for unprotected glass roofs a low one.
What g-value does triple glazing have?
Typical triple-glazed thermal insulation glass with argon fill and two coatings has a g-value of about 0.5 to 0.6. Double glazing is at about 0.6 to 0.72, solar control glass at about 0.27 to 0.48.
Does the g-value say anything about brightness?
Not directly. The g-value covers the entire solar spectrum including infrared. Light transmission is what determines brightness.
Sources
- Gesamtenergiedurchlassgrad – Wikipedia(opens in a new tab)
- Guardian Glass – SunGuard SuperNeutral Produktdaten (Lichttransmission, g-Wert, Selektivität)(opens in a new tab)
- § 14 GModG – Sommerlicher Wärmeschutz(opens in a new tab)
- GModG-Infoportal: Anforderungen an Wohngebäude (Neubau)(opens in a new tab)
- Isolierglas – Wikipedia(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.