Skip to content

Business customers only (B2B) · All prices net plus VAT

AluKun
Window profiles

Aluminium Windows with a Thermal Break: How a Metal Frame Insulates

6 minutes read

Thermal break means that an aluminium window profile consists of an inner and an outer metal shell joined only by plastic insulating struts, usually glass-fibre-reinforced polyamide. These struts interrupt the flow of heat through the highly conductive aluminium. The wider and better insulated this insulation zone is, the lower the Uf-value of the frame.

Why aluminium needs a thermal break

Aluminium is strong, dimensionally stable and weather-resistant, but it conducts heat very well. A continuous aluminium profile would carry heat from inside to outside like a heat sink. The consequences would be high heat losses, cold frame surfaces and condensation on the frame on the room side.

The solution is structural: the profile is split into two halves and joined with a material that conducts heat poorly but reliably transfers the forces from sash weight, wind and operation. This construction is now standard for windows in heated rooms; uninsulated profiles are found almost only in unheated areas such as internal partitions or outbuildings.

Construction of a thermally broken profile

Component Function
Outer aluminium shell Weather protection, colour outside, glazing bead
Insulating struts Join the shells, interrupt the flow of heat
Insulation zone between the struts Cavities or insulating foam reduce convection and radiation
Inner aluminium shell Hardware seating, colour inside
Sealing levels Stop or centre seal separate the rain and wind side from the room side
Glazing Usually double or triple insulating glass with a warm edge

Polyamide insulating struts

The struts are extruded plastic profiles. The manufacturer Technoform describes polyamide profiles as the link between the aluminium parts, whose cavities minimise the exchange of convective and radiant heat; besides standard polyamide, recycled, bio-based and particularly low-conductivity polyamide are offered, as well as variants with polyamide foam. ELVIAL, for example, gives 24 mm wide struts with 25 % glass-fibre reinforcement for its W59 SI² system.

For the AWS 75.SI+ and AWS 70.HI systems, Schüco lists foam-composite insulating struts of Polythermid or polyamide.

Insulation zone and centre seal

Modern systems fill the space between the struts with insulating foam or divide it into several chambers. A large-volume centre seal, expressly named for Schüco AWS 75.SI+, divides the rebate into an outer and an inner zone and improves thermal, sound and driving-rain protection. Additional insulating elements in the glazing rebate reduce losses at the transition between frame and glass.

Frame depth and Uf-value: what the figures show

Frame depth describes how deep the profile is from outside to inside. More depth leaves room for wider insulating struts and more insulation. Examples from manufacturer data:

System Outer frame depth Uf-value according to manufacturer
Schüco AWS 75.SI+ 75 mm Up to 0.92 W/(m²K) (system datasheet) or up to 0.9 W/(m²K)
Schüco AWS 90.SI+ 90 mm Up to 0.71 W/(m²K)
ELVIAL W59 SI² 59 mm Depending on specification, see manufacturer

The "up to" values apply to the best specification variant in each case. Which Uf-value applies to your specific window is stated in the quote or the declaration of performance. How Uf, Ug and Uw relate is explained in Uw, Ug, Uf: the U-values of a window. A direct comparison of two systems is offered in Schüco AWS 75 vs. AWS 90.

Frame is not the same as window

The Uw-value of the whole window depends heavily on the glazing. An aluminium frame with a very good Uf-value is of little use if the glazing is weak; conversely, a slightly worse frame with high-quality triple glazing can perform well overall. For legal requirements, the Uw-value is what counts. In Germany, under Annex 7 of the Building Modernisation Act (GModG, successor to the GEG since 29 July 2026), a maximum value of 1.3 W/(m²K) applies when replacing windows in residential buildings, and 1.6 W/(m²K) for lift-and-slide and other window doors with a sliding mechanism (as of September 2026). These are German requirements; if you live elsewhere, please check your local building regulations.

Advantages and limits of aluminium windows

Advantages:

  • high stiffness, allowing slim sightlines and large sashes,
  • weather-resistant, powder-coated or anodised surfaces,
  • different colours inside and outside thanks to the separate shells,
  • long service life with little maintenance.

Limits:

  • more complex to manufacture than uPVC, so generally a higher price,
  • very good insulation values only with a wide, insulated insulation zone,
  • at the coast, a suitable coating is important.

A comparison of the materials is offered in uPVC or aluminium: which window material is worth it?.

How the struts are joined to the aluminium

In manufacture, the outer and inner aluminium shells are extruded separately. The insulating struts are then inserted into grooves in the two shells and mechanically joined so that a single, load-bearing composite profile results. This connection must permanently transfer shear forces, for example when the sunlit outer shell heats up and expands more than the inner shell.

Two practical points follow:

  • Colour and coating: Because inner and outer shells are separate, they can be coated in different colours, for example anthracite outside and white inside.
  • Temperature differences: Dark exterior colours heat up more. Good systems are designed for this; for very large elements in dark colours, it is worth asking the supplier whether the chosen combination is approved.

Areas of use: where aluminium plays to its strengths

Thermally broken aluminium profiles are particularly common where stability and slim frames are wanted:

  • Large windows and floor-to-ceiling elements, where heavy triple glazing has to be carried.
  • Lift-and-slide doors with large sashes; the basics are explained in Lift-and-slide door: construction, function and benefits.
  • Modern architecture with slim sightlines and a colour wish outside.
  • Commercial and multi-family buildings, where façades and windows come from one system.

For smaller standard windows in a detached house, uPVC is often the more economical choice; with timber-aluminium windows, an outer aluminium shell takes over the weather protection of a timber frame.

Condensation and comfort

A good thermal break keeps the room-side frame surface warm. That is not just an energy question: cold frames can form condensation at high humidity, on which mould can settle. So also pay attention to the warm edge in the insulating glass and an airtight connection to the wall.

Checklist: comparing aluminium windows

  1. Ask for the frame depth of outer frame and sash and compare it with the wall build-up.
  2. Type and width of the insulating struts, insulating foam yes or no.
  3. Sealing system: stop or centre seal.
  4. Uf-value of the variant offered, not just the "up to" value.
  5. Uw-value of the specific window with glazing.
  6. Exterior coating, especially at coastal locations.
  7. Colour combination inside/outside and approval for dark exterior colours.
  8. Burglar and sound protection: Schüco lists burglar resistance up to RC 3 and sound insulation up to 48 dB as options for its AWS systems; ask which values the specification offered actually achieves.

Configure aluminium windows

In the configurator you choose aluminium windows with a thermally broken profile, glazing and colours for inside and outside. You will find an overview of all window systems on the windows page.

Frequently asked questions

What does thermal break mean for aluminium windows?

The profile consists of an inner and an outer aluminium shell joined by plastic insulating struts, usually glass-fibre-reinforced polyamide. The struts interrupt the flow of heat through the highly conductive metal.

Are aluminium windows less well insulated than uPVC windows?

Not necessarily. Modern thermally broken systems achieve good Uf-values; Schüco, for example, gives Uf-values of up to 0.71 W/(m²K) for AWS 90.SI+. Simple systems with a narrow insulation zone are considerably higher; the specific profile is what counts.

Which Uw-value is required when replacing windows in Germany?

Under Annex 7 of the German Building Modernisation Act (GModG), new windows in residential buildings must not exceed a Uw-value of 1.3 W/(m²K) (as of September 2026). This applies to aluminium just as to uPVC or timber. Readers elsewhere should check local requirements.

Are there still aluminium windows without a thermal break?

Uninsulated profiles are now used mainly for unheated areas such as internal partitions, unheated conservatories or outbuildings. For heated living spaces, thermally broken systems are the standard.

Sources

  1. Schüco: Aluminiumfenster für Privatkunden (AWS 75.SI+, AWS 90.SI+)(opens in a new tab)
  2. Schüco AWS 75.SI+ / AWS 70.HI – Systemdatenblatt(opens in a new tab)
  3. Technoform: Standard-Isolierprofile für Fenster, Türen und Fassaden aus Aluminium(opens in a new tab)
  4. ELVIAL W59 SI² CE – Produktdaten(opens in a new tab)
  5. Anlage 7 GModG – Höchstwerte der Wärmedurchgangskoeffizienten(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

Cover image: uPVC Windows Lifespan: How Long Do They Last?
Window profiles

uPVC Windows Lifespan: How Long Do They Last?

uPVC window lifespan and recycling: how long PVC windows last, what determines durability and how old windows are recycled through the Rewindo scheme.

6 minutes read

Cover image: Wooden Window Maintenance: How Much Work Is It?
Window profiles

Wooden Window Maintenance: How Much Work Is It?

Maintaining wooden windows: how often repainting is needed, how to spot the right time, stain or opaque paint, and when timber-aluminium is the alternative.

6 minutes read