Schüco AWS 75 vs AWS 90: Differences, Performance Figures and Uses
6 minutes read
In a Schüco AWS comparison of AWS 75.SI+ and AWS 90.SI+, the rule of thumb is simple: AWS 75.SI+ covers the requirements of most residential buildings, including BEG funding, while AWS 90.SI+ is the system for Passivhaus and very ambitious new builds. The difference lies in 15 mm more frame depth, a larger insulation zone and therefore lower Uf-values. For burglar resistance and hardware load, the two systems are level.
The two systems side by side
| Feature | AWS 75.SI+ | AWS 90.SI+ |
|---|---|---|
| Frame depth of outer frame | 75 mm | 90 mm (sash 100 mm) |
| Uf-value according to Schüco | from 0.92 W/(m²K); 1.2 (PT) / 1.3 (PA) W/(m²K) at 117 mm | 0.80 W/(m²K) at 117 mm (optimized) |
| Example Uw with Ug 0.6 | 0.90 (PT) / 0.93 (PA) W/(m²K) | 0.80 W/(m²K) |
| Passivhaus | not designed for it | certifiable with a special profile combination |
| Burglar resistance | up to RC 3 | up to RC 3 |
| Sash weight | hardware up to 250 kg | AvanTec up to 250 kg |
| Glass thickness | sash 19–65 mm, fixed light 19–55 mm | up to 68 mm according to dealers |
| Sound insulation | up to Rw 48 dB | up to 47 dB according to dealers |
Sources: Schüco product pages, Schüco BIM data and Schüco system documents (as of September 2026). Where only dealer information is available, this is noted – have these values confirmed for your design.
What the 15 mm difference does
Insulation zone
In aluminium windows, plastic insulation bars sit between the outer and inner shell. The deeper the profile, the wider this zone can be, and the more room remains for insulating inserts. That is the main reason for the lower Uf-value of AWS 90.
Installation position
A deeper frame is easier to integrate into the insulation plane of an insulated external wall. That reduces thermal bridges at the connection – a factor that Passivhaus explicitly takes into account with the "installed" value.
Space in the reveal
Conversely, AWS 90 needs more depth. In existing buildings with narrow rebates, that can lead to more complex connections, such as frame extensions or adjustments to the internal window board.
Funding: what is enough for what?
When replacing windows in residential buildings in Germany, the GEG requires Uw ≤ 1.3 W/(m²K) – both systems clearly meet that. For BEG individual-measure funding, Uw ≤ 0.95 W/(m²K) applies. The basic funding rate is 15%; according to BAFA, the 5% iSFP bonus applies only from €30,000 of eligible minimum investment for one residential unit (as of September 2026). These are German rules; in the UK or elsewhere, check the local thermal limits and funding schemes.
- AWS 75.SI+: with PT insulation bars and good triple glazing, the threshold is reachable according to the Schüco example. With small windows or PA bars it can get tight.
- AWS 90.SI+: clear reserve, even with unfavourable formats.
If you only want to reach the funding threshold, AWS 75.SI+ is usually the more economical choice. Details on the application are in the article BAFA funding for windows 2026.
Similarities that are often overlooked
- Security: both platforms can be built up to RC 3.
- Large formats: with the right hardware, both allow sash weights up to 250 kg.
- Surfaces: both are powder-coated or anodised, and can be finished in different colours outside and inside.
- No steel: aluminium profiles need no steel reinforcement, which allows slim sightlines.
You will find the basics of the individual systems in the articles Schüco AWS 75.SI+ and Schüco AWS 90.SI+.
Decision guide
| Project | Recommendation | Reason |
|---|---|---|
| Renovation without funding | AWS 75.SI+ | GEG clearly exceeded, smaller frame depth |
| Renovation with BEG funding | AWS 75.SI+ with PT bars | funding threshold reachable |
| Renovation with many small windows | consider AWS 90.SI+ | more reserve with a high frame share |
| New-build efficiency house | AWS 75.SI+ or AWS 90.SI+ | depending on energy concept |
| Passivhaus | AWS 90.SI+ in certified combination | PHI proof |
| Floor-to-ceiling glazing with heavy glass | both possible | hardware load up to 250 kg |
A simplified calculation for perspective
A rough calculation shows why the Uf-value weighs more on small windows: if the frame takes up 35% of the window area, a Uf-value that is 0.4 W/(m²K) better shifts the Uw-value, through the frame alone, by around 0.14 W/(m²K). On a large window with a 20% frame share it is only about 0.08 W/(m²K). The example is deliberately simplified – the influence of the glass edge (psi-value) comes on top. But it shows why a house with many small windows benefits more from AWS 90 than one with large glazed areas.
Installation and connection
Both systems require professional installation following the principle "tighter inside than outside". With AWS 90, the greater frame depth and the 100 mm sash take up more reveal area. In renovation that can mean that internal plaster or the internal window board must be adjusted. In new build the installation position can be planned freely, ideally in the insulation plane. With both systems, clarify early how roller shutter or external venetian blind boxes are connected – they often affect the thermal bridge at the lintel more than the choice between 75 and 90 mm.
Maintenance
Care hardly differs: check and lubricate hardware annually, clean seals, keep drainage openings clear, and clean surfaces with mild cleaners. With concealed hardware such as AvanTec, adjustment is made via the hinges in the rebate – a specialist firm should do that.
Cost perspective
Specific prices depend on size, opening type, colour, glass and hardware. AWS 90 tends to cost more than AWS 75 – through more material, a more elaborate insulation zone and usually thicker glass. Whether the extra cost pays off depends on how ambitiously the rest of the building is planned: a Passivhaus window in an otherwise moderately insulated house is partly wasted, because walls, roof and connections dominate the heat loss.
Combining both in the same building
Both platforms can be combined in one building, for example AWS 90 on the large south-facing windows and AWS 75 in ancillary rooms. Because face widths and profile geometries differ, agree the façade effect with the designer beforehand. Colours and surfaces can be made identical.
Questions to ask the supplier
- Which profile combination and face width does the stated Uf-value apply to?
- Are PT or PA insulation bars used?
- What Uw results for each individual window with the glazing offered?
- Which hardware is planned – visible or concealed – and which sash weights are approved?
- With AWS 90, is the PHI-certified combination offered, if a Passivhaus proof is needed?
- Which security class (RC 2 or RC 3) is actually tested with the equipment offered?
Checklist for the decision
- Review the energy concept: what Uw makes sense for the building?
- Measure the reveal depth – does a 90/100 mm profile fit without alterations?
- List the number and sizes of windows: many small windows favour AWS 90.
- Clarify the funding need and have Uw calculated per window.
- Have the insulation bar (PT/PA) and profile combination stated in the quote.
- Plan the installation situation, ideally with an energy consultant.
At AluKun you configure both systems in the configurator. You will find an overview of aluminium and uPVC windows on the windows page.
Frequently asked questions
What is the main difference between Schüco AWS 75 and AWS 90?
The frame depth and with it the size of the insulation zone: 75 mm versus 90 mm (sash 100 mm). AWS 90 reaches lower Uf-values and can be Passivhaus-certified with a special profile combination.
Is AWS 75.SI+ enough for BAFA funding?
In many cases yes. Schüco quotes an example with Uw 0.90 W/(m²K) at Ug 0.6 W/(m²K) and PT insulation bars. German funding requires Uw ≤ 0.95 W/(m²K) – the proof is made per window.
When should I choose AWS 90 instead of AWS 75?
For Passivhaus projects, for very high efficiency targets in new build, and when you want a clear reserve on the Uw-value, for example with many small windows with a high frame share.
Are both systems equally burglar-resistant?
According to Schüco, both platforms can be built up to RC 3 under DIN EN 1627. The class achieved depends on the hardware, glass and handle of the specific order.
Sources
- Schüco – AWS 75.SI+ (Produktseite)(opens in a new tab)
- Schüco Window AWS 75.SI+ – BIMobject (Herstellerdaten)(opens in a new tab)
- Schüco Systemeigenschaften AWS 75.SI (PDF)(opens in a new tab)
- Schüco – AWS 90.SI+ (Produktseite)(opens in a new tab)
- Schüco – AWS 90.SI+ optimized (Produktseite)(opens in a new tab)
- Schüco Window AWS 90.SI+ – BIMobject (Herstellerdaten)(opens in a new tab)
- BAFA – BEG Einzelmaßnahmen Gebäudehülle(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.