RAL installation: what is behind professional window fitting
7 minutes read
RAL installation means fitting a window according to the "Guideline for planning and carrying out the installation of windows and front doors", which the RAL Quality Association for Windows, Facades and Front Doors publishes together with ift Rosenheim. At its core are three things: a load-bearing fixing, clean load transfer via packers and sealing of the installation joint on the principle "tighter inside than outside". The guideline is not a law but is regarded as a description of the recognised rules of technology. It is a German document; in the UK, installation is usually carried out under a competent person scheme such as FENSA and the relevant Approved Documents, so ask your installer which guidance they follow.
A good window can only hold its values if it is installed correctly. That applies equally to thermal protection, sound insulation, airtightness and burglar protection.
What the RAL guideline is
The guideline is a planning and execution manual for window fabricators, designers and clients. It describes how windows and front doors are fixed and connected in the building. The revised edition appeared in March 2020. According to ift Rosenheim, the following, among other things, were taken into account:
- current standards on thermal protection (DIN 4108) and sound insulation (DIN 4109)
- the standard for joint sealing tapes (DIN 18542)
- the standards on waterproofing of structures (DIN 18531 and 18533)
- requirements on burglar resistance and fall protection
- newly calculated Ψ values and temperature factors for thermal bridges
- simplified standard cases for fixing
Also newly included are notes on accessible thresholds and on two-stage installation with pre-wall or mounting frames.
Legal status
RAL installation is not a legal obligation. Contracts for work, however, owe installation according to the recognised rules of technology, and the guideline is regarded as their description. In the event of damage, experts therefore often examine whether the installation meets this standard. For funded measures, German BEG and ESanMV require execution with minimal thermal bridging and airtightness; in practice, installation to the RAL guideline is the obvious route to that. This article does not replace legal advice.
RAL installation of windows: the three tasks
1. Fixing
The window must be anchored in the wall so that it permanently takes wind loads, the forces of use when opening and closing, and its own weight. Fixing is all round, including top and bottom, with frame plugs, screws or mounting anchors. Which fixing suits depends on the masonry: concrete, solid brick, perforated brick, aerated concrete or timber need different solutions. The spacing of the fixing points follows the guideline and manufacturer's specifications; spacings that are too large cause profiles to deform and seals to stop sitting evenly.
2. Load transfer
The weight of frame, sash and glass is not carried through the screws but through load-bearing and spacer packers into the wall. The load-bearing packers stay permanently under the frame, especially at the points where the sash load arrives. Fitting wedges that only help with alignment are removed or replaced afterwards. Foam is not a load-bearing fixing.
3. Sealing the installation joint
The joint between frame and wall is made in three layers:
| Layer | Position | Task |
|---|---|---|
| Inside | room side | airtight and vapour-retarding |
| Middle | functional zone | thermal and sound insulation |
| Outside | weather side | driving-rain-tight but vapour-open |
The basic principle is "tighter inside than outside": moisture from the room must not get into the joint, and moisture in the joint should be able to dry outwards. How the layers are built up in detail is explained in the article on the three-layer principle in window installation.
Typical mistakes that RAL installation avoids
- Only expanding foam: foam insulates but is neither airtight nor driving-rain-tight and is not a fixing.
- Silicone outside, nothing inside: the joint is tighter outside than inside, so room moisture condenses in the joint.
- Missing packers: the frame hangs on the screws, deforms, and sashes rub.
- Too few fixing points: profiles bend under wind, seals do not sit tight.
- No planning of the window sill: water runs under the frame instead of out. Matching connecting profiles help here, see sill connecting profiles.
- Installation position with no regard for the insulation: thermal bridges arise at the reveal.
Installation and burglar protection
With burglar-resistant windows, installation is part of the protection. An RC2 window must be fixed to the manufacturer's specifications and packed pressure-resistantly in the area of the locking points. Otherwise the burglar can push the frame out of the wall even though hardware and glass hold. The police point out that windows are mostly levered open with simple tools, and the fixing must absorb exactly these forces too. More on the classes in the article Burglar protection for windows: RC1 to RC3.
Special cases: pre-wall installation and large elements
With insulated facades with an external wall insulation system, the window is often fitted in front of the masonry in the insulation plane. Mounting systems with brackets, angles or mounting frames exist for this, which take the weight and the wind loads. This pre-wall installation avoids thermal bridges at the reveal but requires careful planning of load transfer and of sealing to the insulation.
Large elements such as lift-and-slide doors or panoramic windows place high loads on the threshold and the fixings. Support profiles or substructures are usual here, and the sealing of the threshold is part of the waterproofing of the structure. For floor-to-ceiling elements, the revised guideline recommends accessible thresholds in combination with compensating measures such as drainage channels and canopies.
What you can check as a client
You do not have to be a specialist to check the most important points. Look at the open joint before plastering:
- Are sealing tapes or membranes stuck continuously and without gaps all round on the inside?
- Is there a compressible sealing tape, a membrane or another driving-rain-tight system on the outside?
- Is the joint fully insulated, without voids?
- Are there load-bearing packers under the frame?
- Are fixings visible all round, including top and bottom?
Take photos before the joint is plastered or clad. They document the installation for funding, the tax bonus and any warranty question.
Installation when replacing windows in existing buildings
In an older building the wall is seldom level, the reveal is often damaged, and old connections have to be removed. The guideline offers solutions for this too, for example with connecting profiles or frame extensions. What matters is to prepare the substrate for the sealing tapes: many tapes need a smooth, sound surface. With very uneven reveals, a smoothing coat is applied first. If you want to install the windows yourself, you should know the limits described in the article on installing windows yourself.
Checklist for your quotation
- Agree installation to the RAL guideline expressly in the quotation
- Have the type of fixing stated to suit the masonry
- Have the sealing system named inside and outside
- Have the insulation of the joint and the connection of the sill described
- For RC windows, follow the manufacturer's installation specifications
- Agree photo documentation before plastering
- Carry out the handover together and check the function of all sashes
Window fabricators and installation firms obtain made-to-measure windows through the AluKun B2B portal. For your project, put windows, connecting profiles and frame extensions together in the configurator; our team answers questions about installation situations via the contact page.
Frequently asked questions
What does RAL installation mean for windows?
The term stands for window installation following the guideline for planning and carrying out the installation of windows and front doors, published by the RAL Quality Association for Windows, Facades and Front Doors and ift Rosenheim. It describes fixing, load transfer and sealing of the installation joint.
Is RAL installation required by law?
No, the guideline is not a law. It is, however, regarded as a description of the recognised rules of technology. In a dispute, experts and courts often look at whether the installation meets this standard.
What does RAL installation cost?
The cost depends on window size, connection situation, sealing material and regional prices. Only quotations that describe the same services, such as fixing, sealing tapes inside and outside and insulation of the joint, can be compared reliably.
Which edition of the RAL guideline is current?
The revised edition was published in March 2020. It takes account of, among other things, updated standards on thermal protection, sound insulation, joint sealing tapes and waterproofing of structures.
Sources
- ift Rosenheim – Update Montageleitfaden Fenster und Außentüren(opens in a new tab)
- widuro – Fenstereinbau nach RAL (anerkannte Regeln der Technik)(opens in a new tab)
- dbfenster – Innen dichter als außen: Die drei Ebenen der Anschlussfuge(opens in a new tab)
- ESanMV Anlage 4 – wärmebrückenminimierte und luftdichte Ausführung(opens in a new tab)
- Polizeiliche Kriminalprävention – Einbruchschutz am Fenster(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.