Window-Sill Connection Profile (FBA): How to Get a Clean Connection at the Bottom of the Window
6 minutes read
The window-sill connection profile (FBA, from the German Fensterbankanschlussprofil) is an unassuming but important additional profile under the outer frame that enables the connection of external window sill and internal window board. 30 mm height is usual. It ensures that the external window sill can be pushed under the frame and fixed, separates inside from outside and protects the window during transport. Important when ordering: clarify whether the stated window height includes the FBA.
What the window-sill connection profile does
Connecting the external window sill
The external window sill – usually aluminium – is pushed under the FBA or fixed to it. According to fenster24, aluminium window sills can be screwed directly to the sill connection, which ensures professional installation. The water then runs from the window over the sill to the outside without getting behind the sill.
Connecting the internal window board
Inside, the internal window board butts against the profile. fenster-sofort describes the internal window board as being connected to the connection profile rather than directly to the main frame. That eases installation and relieves the frame.
Transport protection
An often overlooked benefit: the FBA protects the outer frame during transport, because the window does not stand directly on the frame. Damage to the underside of the frame, which would later impair sealing, is thus avoided.
Separation of inside and outside
The profile creates a defined separation plane between internal and external sill. That is the basis for clean sealing: airtight inside, driving-rain-tight outside.
Typical heights and versions
| Height | Use |
|---|---|
| 30 mm | standard in new build and renovation |
| 40 mm | special cases, e.g. taller sill build-ups |
| 60 mm | renovation with larger height compensation |
According to fenster24, the 30 mm profile is the most common variant. The 30 mm profile described by fenster-sofort has five chambers and is thus built like the window profile itself. Which heights are available for your profile system is set by the manufacturer.
The FBA and your order size
This is where most mistakes happen in practice. Many suppliers state the window height without the window-sill connection profile. The FBA then comes on top, under the frame. Worked example:
- Structural opening (height): 1,300 mm
- Window height as ordered (without FBA): 1,240 mm
- plus FBA: 30 mm
- gives element height: 1,270 mm
- remaining joint: 30 mm for installation and sealing
Fenster-sofort points out that, besides the 30 mm of the profile, space for the connection joint must also be planned. Anyone who forgets the FBA orders a window that is too tall for the opening. More on measuring in the article Measuring windows correctly.
Tip: check with every supplier whether the height means with or without FBA, and note it on your dimension list.
FBA and sealing
The bottom connection is the most critical point of a window, because water runs off the pane and frame here. The three-level principle has proven itself:
- Inside: airtight connection tape between frame or FBA and wall.
- Middle: insulation of the joint.
- Outside: driving-rain-tight but vapour-permeable sealing; beneath it, where needed, a second water-carrying level under the sill.
The external window sill must have a fall to the outside, be connected at the sides with end profiles or end pieces, and project beyond the façade. The basics are described in the article Tight inside, open outside: the three-level principle.
FBA and roller shutters
With windows fitted with front-mounted or surface-mounted roller shutters, the guide rails usually end on the external window sill. The sill must therefore be fitted before the roller shutter or given suitable cut-outs. Plan FBA, window sill and roller shutter rails together so that no water traps arise. More in the article Window sill and roller shutter.
When an FBA does not fit
- Floor-to-ceiling windows and doors: here a floor bearing or a frame extension replaces the FBA.
- Stone window sills: for natural or artificial stone sills there are sometimes dedicated connection profiles; sealing is done differently from aluminium sills.
- Special wall build-ups: with face-fixed installation in the insulation plane, installation frames or brackets are often used that take over the bottom connection.
For other adjustments to the frame, frame extensions come into question – see Frame extensions and coupling profiles.
Material and quality of the external window sill
The FBA is only the connection surface – the actual water drainage is done by the external window sill. Aluminium is the most common material: light, dimensionally stable and powder-coated in many colours. Important are:
- Projection: the sill should project well beyond the finished façade so that draining water does not run down the wall.
- Fall: an adequate fall to the outside prevents standing water.
- Side connections: end profiles or end caps that absorb movement from temperature changes without cracking the render.
- Anti-drumming coating: it dampens the noise of raindrops.
The Austrian guideline for the installation of window sills from the Wirtschaftskammer (Austrian Economic Chamber) describes these requirements in detail; in Germany, comparable technical rules of the window-making and plastering trades apply.
Connecting the internal window board properly
Inside, the window board connects to the FBA or the frame. An elastic joint belongs between internal window board and frame; beneath it, the airtight connection tape. The material and depth of the internal window board depend on reveal depth and radiator: a window board that is too deep above the radiator can obstruct air circulation in front of the pane and encourage condensation.
Common mistakes
- FBA forgotten: the window does not fit the opening, or the connection surface for the window sill is missing.
- Wrong height: an FBA that is too low leaves no room for the window sill and its fixing; one that is too tall needlessly wastes glass area.
- No sealing under the window sill: water runs behind the sill and soaks the masonry.
- Colour not matched: on coloured windows the FBA must be ordered in the same decor, otherwise a visible white strip remains under the frame.
FBA on windows with a frame extension at the bottom
Sometimes 30 mm is not enough, for example when the old parapet was higher at the window replacement or thick external insulation has to be connected. Then taller connection profiles or a combination of extension and FBA are used. What matters is that the sealing levels remain continuous and the water is still safely led onto the external window sill. Clarify such build-ups with the window maker before ordering.
Checklist
- Clarify the order size: height with or without FBA?
- Choose the FBA height: standard 30 mm, special heights depending on the situation.
- Plan the window sill: material, projection, fall, side connections.
- Decide the sealing: airtight inside, driving-rain-tight outside.
- Take any roller shutter into account.
- Order the colour of the FBA to match the window.
- Match the internal window board in depth and material to the reveal and radiator.
- Check the installation: has a second water-carrying level been formed under the external window sill?
In the AluKun configurator you select the window-sill connection profile together with the window. We are happy to answer questions about dimensions, window sills and connections through the contact form – ideally with photos of the installation situation.
Frequently asked questions
What is a window-sill connection profile?
An additional profile fitted under the outer frame of the window. It creates the connection surface for the external window sill and internal window board and protects the frame during transport.
How high is a window-sill connection profile?
30 mm is usual. For special cases, such as in renovation, there are also taller profiles of 40 or 60 mm, depending on the profile system.
Is the FBA included in the window size?
That differs by supplier. Many shops state the window height without the FBA. Always check whether the height ordered means with or without the window-sill connection profile.
Do I need an FBA with a stone window sill?
Even with natural-stone or concrete sills, a lower connection is needed so that water is drained safely and the frame is sealed correctly. There are sometimes dedicated connection profiles for stone sills; the solution depends on system and installation situation.
Sources
- fenster24 – Fensterbank-Anschlussprofile richtig auswählen(opens in a new tab)
- fenster-sofort – Was ist ein Fensterbankanschlussprofil?(opens in a new tab)
- fensterblick – Fensterbankanschlussprofile (FBA) aus Kunststoff(opens in a new tab)
- WKO – Richtlinie für den Einbau von Fensterbänken (PDF)(opens in a new tab)
- fensterblick – Rahmenverbreiterungen für Fenster und Haustüren(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.