External and Internal Window Cills: Materials, Fall and a Watertight Connection to the Window
6 minutes read
An external window cill must above all drain water reliably: with a fall outwards, a projection beyond the finished façade and a drip edge that keeps rain away from the wall. Manufacturer guidelines typically give at least 5 degrees of fall and around 40 mm of projection for this. The internal window cill (window board), by contrast, is mainly a question of look, material and the airtight connection to the window.
Window cills are readily treated as an afterthought when windows are replaced. Yet many moisture problems arise precisely at the lower window connection. This article shows what matters inside and outside. The guideline figures come from German manufacturer and agency guidance; for other countries, please check local building practice.
External window cill: tasks and requirements
The external cill protects the parapet from driving rain and carries water that runs down the pane away from the façade. For this to work, several details must be right:
- Fall: The Helopal installation guideline gives at least 5 degrees of slope outwards. Standing water on the cill is a warning sign.
- Projection: The cill should project about 40 mm beyond the finished façade surface. For natural-stone cills, a minimum distance of 30 mm of the drip edge from the façade is also given.
- Drip edge: A fold or groove on the underside prevents water running back along the underside to the wall.
- Side ends: End stops or sliding end caps close the cill against the reveal and absorb changes in length.
- Rear connection: The cill must engage under the window, for example via a cill connection profile, and must not cover the frame's drainage openings.
Second water-bearing level
Window cills are rarely completely watertight: joints, end stops and fixings can let water through. In many cases, guidelines therefore call for a second water-bearing level under the cill, such as a waterproofing membrane or a coated parapet. This is particularly important if the cill is fitted after the façade render or the building is timber-framed. How the levels at the window work together is described in Sealed inside, open outside.
Materials for the external window cill
| Material | Strengths | Points to note |
|---|---|---|
| Aluminium (coated or anodised) | Light, many colours, matching end stops, good adaptation to external insulation | Expansion on long cills, rain noise possible, anti-drumming coating sensible |
| Natural stone (e.g. granite) | Very robust, durable, solid look | Heavy, needs a load-bearing base and careful sealing |
| Cast stone | Can be shaped, robust | Weight, joints and sealing as with natural stone |
| Clinker/brick-on-edge course | Traditional look on clinker façades | Many joints, sealing underneath particularly important |
For aluminium over 3 m long, the Helopal guideline names expansion joints as necessary, because the material expands with temperature changes. On aluminium cills, an anti-drumming coating on the underside reduces drumming in rain.
Internal window cill: materials and dimensions
Inside, what matters most is what suits the room and is robust in everyday use:
- Natural stone and agglomerate/cast stone: hard, scratch-resistant, cool to the touch, good for plants and use as a shelf.
- Wood: warm but sensitive to standing moisture; use plant pots with saucers.
- Wood-based board with plastic coating: inexpensive, many finishes, easy to care for.
- Mineral composites: jointless and easy to care for, more in the upper segment.
Do not cover the radiator
If a radiator sits under the window, the internal cill should be sized so that warm air can rise in front of the pane. The German Federal Environment Agency points out that oversized window cills, casings or heavy curtains can prevent rooms from getting warm enough, which raises the risk of condensation and mould.
For the depth of the internal cill, many planners take the wall depth plus a small projection into the room. If you want to put plants or decoration on it, choose it somewhat deeper, but then keep an eye on the radiator.
Internal connection
The internal cill sits in front of the window's room-side seal. It is important that the airtight membrane or sealing tape between frame and masonry is not damaged. The joint between cill and frame is closed with an elastic sealant so that it can absorb movement.
Window cills when replacing windows: typical situations
The old cill stays
If the old external cill is intact and the height fits, it can stay. Often, however, the connection no longer fits because the new window has a different frame depth or installation position. Then cill connection profiles or build-ups help; more in the article on the cill connection profile (FBA).
New cill with insulation
If the façade is insulated, the outer edge moves forward. The new cill must then cover the additional projection and be connected to the render system via suitable end profiles. Clarify this with the façade contractor before ordering windows and cills.
Deep reveals and floor-to-ceiling windows
With thick walls and a window set to the inside, deep external reveals result. The external cill becomes correspondingly long and must be made with particular care for fall and side ends, because more water drains over a larger area. For floor-to-ceiling windows and window doors, the cill is often omitted altogether; there, threshold connections, drainage channels or grilles take over the water drainage. These details belong in the detailed design, not on site.
Roller shutters and cills
Guide rails of roller shutters often stand on the cill or end just above it. Leaks easily arise here. How to plan this interface properly is shown in Window cill and roller shutter: planning the connections.
Common damage and its causes
Most problems with window cills show up only years after installation. Typical damage patterns are:
- Damp parapet or render flaking under the cill: Water gets behind the cill via open joints or side connections because the second water-bearing level is missing.
- Dirt streaks on the façade: The projection is too small or the drip edge is missing, so water runs down the wall.
- Cracks in the render at the reveals: The cill expands without end stops or sliding end caps absorbing the movement.
- Water on the internal cill: Often the cill is not to blame but blocked drainage slots in the frame or condensation on the pane.
When checking after installation, a short water test is therefore worthwhile: pour water from a watering can onto the cill and watch whether it drains quickly over the drip edge and the side connections stay dry. More on checking new windows is in Acceptance and handover.
Checklist for window cills
- Determine the façade build-up: with or without additional insulation.
- Choose the depth of the external cill so that about 40 mm of projection beyond the finished façade results.
- Ensure fall outwards and a drip edge.
- Plan side end stops and expansion compensation.
- Provide a second water-bearing level under the cill where the guideline requires it.
- Keep the window frame's drainage openings clear.
- Size the internal cill so that it does not cover the radiator.
When ordering new windows, you should think about frame depth and connection profiles straight away. In the window configurator you choose profile and accessories; for queries about connections, you can reach our team via the contact page.
Frequently asked questions
How much fall does an external window cill need?
Manufacturer guidelines give external window cills a fall of at least 5 degrees outwards so that rainwater drains quickly. The exact figure depends on the system and the installation situation.
How far must the external window cill project?
A projection of about 40 mm beyond the finished façade surface is usual, so that the drip edge keeps water away from the wall. With insulated façades, a correspondingly deeper cill must be chosen.
Which material is best for the external window cill?
Aluminium is light, available in many colours and easy to seal with end stops. Natural stone is very robust but heavier and needs careful sealing underneath. The choice depends on façade, look and budget.
May the internal window cill project over the radiator?
A large projection over the radiator can hinder heat output. The German Federal Environment Agency expressly names window cills that are too large as a possible reason why rooms do not get warm enough.
Sources
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.