Skip to content

Business customers only (B2B) · All prices net plus VAT

AluKun
Window profiles

Frame Uf-Value: How to Compare Window Profiles Properly

7 minutes read

The frame Uf-value describes how much heat is lost through outer frame and sash – in W/(m²K), the lower the better. According to manufacturers, current uPVC and aluminium systems lie between about 0.8 and 1.3 W/(m²K), simpler aluminium profiles well above. For a fair comparison you need to know which profile combination the value applies to and how it feeds into the Uw-value of the whole window.

Uf, Ug, Uw: the three U-values of a window

Abbreviation Meaning Applies to
Uf frame outer frame and sash
Ug glazing centre of glass
Uw window whole window

The Uw-value is calculated from the other values under DIN EN ISO 10077-1. Baunetz Wissen gives the formula as follows:

Uw = (Ag × Ug + Af × Uf + lg × Ψg) / (Ag + Af)

Here Ag and Af are the visible areas of glass and frame, lg is the visible perimeter of the pane and Ψg is the linear heat loss at the glass edge (spacer). The Uf-value itself is calculated numerically for the frame cross-section under DIN EN ISO 10077-2.

The basics of all three values are explained in the article Uw, Ug, Uf: the U-values of a window.

Why "Uf up to …" must be read carefully

Manufacturers mostly state the best value of a system. For the 88 mm standard system, Kömmerling quotes "Uf-values of 0.93 to 0.98 W/(m²K), depending on the version", for example. The value depends on:

  • Profile combination: which outer frame with which sash? Mullions and transoms have their own values.
  • Face width: Schüco states Uf for AWS 75.SI+ expressly for a 117 mm face width.
  • Reinforcement: steel worsens the Uf-value, fibre composite can improve it.
  • Insulation bars on aluminium: for AWS 75.SI+ at 117 mm face width, Schüco quotes Uf 1.2 with Polythermid bars and 1.3 W/(m²K) with polyamide bars.
  • Design variant: for K-VISION, Kömmerling quotes Uf 1.4 W/(m²K) in the standard version and down to 1.0 W/(m²K) in an optimised version.
  • Energy level: for W59 SI², Elvial distinguishes three levels with different Uf-values.

A fair comparison therefore requires that the values apply to comparable combinations.

How strongly does the Uf-value affect Uw?

The influence depends on the frame share. A simplified rough calculation (without glass-edge loss) shows the order of magnitude:

Frame share Uf difference 0.2 W/(m²K) Effect on Uw
20% (large window) 0.2 × 0.2 approx. 0.04 W/(m²K)
30% (typical living-room window) 0.2 × 0.3 approx. 0.06 W/(m²K)
40% (small bathroom window) 0.2 × 0.4 approx. 0.08 W/(m²K)

That looks small, but it can decide funding: for German BAFA individual-measure funding, Uw ≤ 0.95 W/(m²K) applies, with a basic funding rate of 15% (as of September 2026). If a small window calculates at 0.98, a better frame can make the difference. Conversely, a very good frame achieves little if the glazing is weak. In the UK or elsewhere, check the local thermal limits and schemes.

Typical Uf-values at a glance

Published manufacturer data (as of September 2026):

System Material Uf according to manufacturer
Kömmerling 70 AD uPVC up to 1.2 W/(m²K)
Kömmerling 76 MD uPVC up to 1.0 W/(m²K)
Schüco LivIng Classic 82 MD uPVC up to 0.96 W/(m²K)
Kömmerling 88 MD uPVC 0.93–0.98 W/(m²K)
REHAU Artevo (LowE) uPVC down to 0.81 W/(m²K)
Schüco AWS 75.SI+ Aluminium from 0.92 W/(m²K)
Schüco AWS 90.SI+ optimized Aluminium 0.80 W/(m²K)
Elvial W59 SI² Aluminium from 1.8 W/(m²K)

What determines a profile's Uf-value

With uPVC windows, four factors mainly influence the frame value:

  • Number and geometry of chambers: more and smaller chambers slow heat conduction, convection and radiation in the profile.
  • Sealing system: a centre seal divides the rebate space and lowers heat loss. Kömmerling quotes Uf up to 1.1 for 76 AD and up to 1.0 W/(m²K) for 76 MD.
  • Reinforcement: steel conducts heat very well; fibre composite or a central position improves the value.
  • Insulating inserts and coatings: foam inserts or the LowE foil in REHAU Artevo max reduce heat transfer in the chambers.

With aluminium windows, what counts above all is the width and material of the insulation bars, insulating inserts in the insulation zone and a large-volume centre seal. With timber windows, the timber species (density) and frame thickness determine the Uf-value.

Uf-value and slimness: a conflict of aims

Narrow profiles look elegant and let more light in. The frame share falls, which helps the Uw-value. At the same time less room remains for insulation in the profile, which can worsen the Uf-value. Manufacturers resolve this conflict with optimised insulation zones and new materials. For you that means: a slightly worse Uf with a markedly narrower frame can end up giving the same or even a better Uw. So decide by the Uw-value of your window, not by Uf alone.

Common mistakes when comparing

  1. Confusing Uf with Uw: a Uf of 0.95 does not mean the window reaches Uw 0.95.
  2. Comparing a best value with a standard value: "Uf up to 0.93" against "Uf 1.0 in the standard version" is not a fair comparison.
  3. Ignoring colour: decor, aluminium shell or additional reinforcement can change the value.
  4. Forgetting the mullion: double-sash windows with a fixed central mullion have more frame area; French-style windows with a meeting stile distribute it differently.
  5. Overlooking installation: the connection to the wall creates its own thermal bridges, which neither Uf nor Uw captures.

Uf-value and installation

Uf and Uw describe the window as a component. How much heat is actually lost also depends on installation. The Passivhaus Institut therefore distinguishes between the window's U-value and the "installed" value, which includes the thermal-bridge loss at the connection. For ordinary renovations that means: a very good frame realises its potential only with a professional, low-thermal-bridge connection. More in the article Thermal bridges at the window connection.

Statutory and funded requirements

When replacing windows in residential buildings in Germany, the GEG requires Uw ≤ 1.3 W/(m²K), 1.4 for roof windows and 1.6 W/(m²K) for lift-and-slide or folding doors (Annex 7, as of September 2026). There are no Uf limits of their own; the frame only has to be good enough for the window as a whole to meet the Uw-value.

A note on the unit: W/(m²K) means watts of heat flow per square metre of area and per kelvin of temperature difference between inside and outside. At 20 °C inside and 0 °C outside, one square metre of frame with Uf 1.0 therefore loses roughly 20 watts in calculation terms.

How to compare quotes properly

  1. Demand Uw per window with your dimensions and the glazing offered.
  2. Ask for the Uf of the specific combination – outer frame, sash and, where relevant, mullion.
  3. Have colour and aluminium shell taken into account.
  4. Check Ug and spacer (warm edge), because they influence Uw at least as strongly.
  5. For aluminium, ask about the insulation bar material.
  6. For funding, agree the proof with the energy efficiency expert before applying.

An overview of uPVC systems is given in the uPVC window profile comparison. In the AluKun configurator you choose profile, glass and spacer and so assemble the values that determine your Uw.

Frequently asked questions

What is the Uf-value?

The Uf-value is the thermal transmittance of the window frame (f for frame) in W/(m²K). It states how much heat is lost per square metre of frame area and kelvin of temperature difference; lower is better.

How is the Uf-value determined?

Under DIN EN ISO 10077-2 it is calculated numerically for a frame cross-section, or alternatively measured. The result applies to the profile combination calculated, for example a particular outer frame with a particular sash.

Which matters more: Uf or Ug?

Both feed into the Uw-value. Because glass usually has the larger share of the area, the Ug-value often dominates. With small windows with a high frame share, the Uf-value gains weight.

Why do manufacturers often say "Uf up to"?

Because the Uf-value varies with the combination of frame, sash, reinforcement, colour or aluminium shell. "Up to" denotes the best value of the system, not the value of every version.

Sources

  1. Baunetz Wissen – Wärmeschutz: U-Wert und Wärmedurchgangskoeffizient(opens in a new tab)
  2. Baunormenlexikon – DIN EN ISO 10077-1(opens in a new tab)
  3. Kömmerling 88 Standard – Produktseite(opens in a new tab)
  4. Schüco Window AWS 75.SI+ – BIMobject (Herstellerdaten)(opens in a new tab)
  5. Kömmerling K-VISION – Produktseite(opens in a new tab)
  6. ELVIAL – W59 SI² CE (Produktseite)(opens in a new tab)
  7. GEG Anlage 7 – Höchstwerte der Wärmedurchgangskoeffizienten(opens in a new tab)

Ready for your project?

Configure your products to measure and see the price straight away – or send us your questions.

We use strictly necessary cookies so the shop, configurator and basket work. With your consent we also use Google Analytics to measure how the site is used, and marketing signals for advertising. You can change your choice at any time in the footer. Read our privacy policy