Avoiding thermal bridges at the window connection: causes, limit values and solutions
7 minutes read
A thermal bridge at a window arises where frame and wall meet so unfavourably that more heat flows outwards than in the surrounding area, usually at the reveal, lintel, roller shutter box and sill. You avoid it by putting the window in the insulation plane, insulating over the frame on the outside, and making the installation joint airtight and fully insulated. As a minimum requirement, DIN 4108-2 demands an inner surface temperature of 12.6 °C under standard conditions. That standard and the figures below are German; in the UK, thermal bridging and condensation risk at junctions are dealt with under Approved Document L and related guidance, so check with your installer or designer which criteria apply.
Thermal bridges cost energy, but above all they endanger the building fabric because moisture collects at cold spots.
Why the window connection is so sensitive
The window is a component in the wall that is built differently from the wall. At its edges, different materials, insulation planes and geometries meet. Specialists distinguish three kinds of thermal bridge, which often occur together at the window:
- Constructional: the window sits in front of, in or behind the insulation plane; lintels, brackets and roller shutter boxes interrupt the insulation.
- Geometric: at the reveal the outer surface is larger than the inner surface, so the corner cools more.
- Material-related: metal fixings, aluminium profiles without a thermal break or reinforced concrete lintels conduct heat particularly well.
Added to this is the edge seal of the glazing. It is a small thermal bridge within the window itself, which a warm edge spacer greatly reduces.
Limit values: 12.6 °C and fRsi 0.70
DIN 4108-2 sets the minimum thermal protection. For thermal bridges the rule is: under the standard conditions of 20 °C room temperature, 50% relative humidity and −5 °C outside temperature, the inner surface at the coldest point must be at least 12.6 °C. That corresponds to a temperature factor fRsi ≥ 0.70.
The value is chosen so that at this point the humidity at the surface does not rise permanently into a range in which mould grows. If it is not met, moisture damage is threatened, even with normal ventilation habits.
For the energy balance, designers allow for thermal bridges through a surcharge on the U-value of the building envelope. A flat 0.10 W/(m²K) is used; for details following recognised examples 0.05 W/(m²K) is possible, and with a detailed assessment the individual thermal bridges are calculated using Ψ values. The German RAL installation guideline adapted its Ψ-value tables and fRsi calculations to the current standards in the 2020 edition.
The typical weak points and solutions
| Weak point | Problem | Solution |
|---|---|---|
| Installation position | window sits inside in uninsulated masonry, insulation ends in front of it | put the window in the insulation plane or insulate over the frame on the outside |
| Reveal | uninsulated reveal cools strongly | external reveal insulation, internal if needed |
| Roller shutter box | old box with thin wall, often leaky | insulate the box or replace it with an insulated top-mounted or surface-mounted box |
| Window sill | continuous stone sill conducts cold inwards | thermal break, insulation under the external sill |
| Lintel | concrete or steel lintel without insulation | insulating over, insulated lintel elements |
| Installation joint | voids or air movement in the joint | full insulation, airtight inside, driving-rain-tight outside |
Installation position in renovation
The most common thermal bridge in existing buildings arises when new windows are fitted in the old position and the facade is insulated later without coordination. The window then sits deep in the wall, the insulation ends at the reveal, and the frame stays exposed on the outside. Plan windows and facade insulation together, ideally with a renovation roadmap. Why this also pays off for funding is explained in the article on the iSFP bonus.
The roller shutter box
Old roller shutter boxes built into the lintel are often the coldest and leakiest spot at the window. When replacing windows there are two routes: insulate and seal the existing box, or replace it with a system with an insulated box. Which roller shutter systems come into question depends on the lintel and the look you want.
The installation joint: insulation and airtightness
A thermal bridge arises not only through too little insulation but also through air movement. If warm, moist room air penetrates a leaky joint, it cools and gives up moisture. Installation with minimal thermal bridging therefore always includes an airtight internal seal. The requirements of the German ESanMV and BEG funding sum this up in the phrase "thermal-bridge-minimised and airtight execution". How the three layers of the joint are built up is covered in the article on the three-layer principle.
Spotting thermal bridges
Many thermal bridges can be found in winter with simple means. A surface thermometer shows whether reveals, corners or the area under the roller shutter box are markedly colder than the wall surface. Dark discolouration, mildew spots or moisture at the window reveal are warning signs. Thermography from outside, best in cold weather and without sunshine, makes thermal bridges visible over a large area. It does not replace expert assessment, however, because reflections and materials can distort the images. If you need more precise values, have the critical connections checked by an energy adviser with a thermal bridge calculation.
A typical case in existing buildings
In many houses from the 1960s to the 1980s, the roller shutter box sits in the lintel, the windows have a continuous stone sill, and the reveals are merely plastered. If only the windows are replaced here, the window remains airtight and well insulated, but its surroundings stay cold. Condensation and mould then migrate to the reveal and the box. If you deal with these spots at the same time, by insulating the box, thermally separating the sill and insulating the reveal, you avoid the consequential damage.
Thermal bridges and funding
German BEG funding and the tax bonus under § 35c require execution with minimal thermal bridging. If you document the details of the installation position and connections, you have a solid basis for the check by the energy efficiency expert and for any warranty questions. Photos of the open joint before plastering are helpful for this.
New build and timber frame construction
In a new build, thermal bridges can be avoided from the start. In masonry construction with an external wall insulation system, the window is often fitted in front of the wall in the insulation plane; special brackets or mounting frames carry the load. In timber frame construction the window sits in the insulated stud plane, and the connections are tied into the airtightness layer and the windproofing with sealing tapes. In both cases the details must be settled before ordering, because frame extensions, connecting profiles and sills are matched to them. You can read more on timber construction in the article on window installation in timber frame construction.
Checklist for a window replacement with minimal thermal bridging
- Fix the installation position in relation to existing or planned insulation
- Plan reveal insulation and insulating over the frame
- Look at the roller shutter box, lintel and sill in detail
- Insulate the installation joint fully and tape it airtight on the inside
- For funded measures, agree the details with the energy efficiency expert
- After the first winter, check reveals and corners for moisture
If you plan your windows together with frame extensions, sill connecting profiles and roller shutter boxes, you can solve many details at the ordering stage. Use the configurator for this and discuss connection situations in existing buildings with our team via the contact page.
Frequently asked questions
What is a thermal bridge at a window?
A spot at the junction between window and wall where more heat flows outwards than in the surrounding area. On the inside this spot is colder; moisture can condense there and mould can form.
What minimum temperature must the window connection have on the inside?
Under standard conditions (20 °C inside, 50% relative humidity, −5 °C outside), DIN 4108-2 requires an inner surface temperature of at least 12.6 °C. That corresponds to a temperature factor fRsi of at least 0.70.
Where should the window sit in the wall?
Ideally in the plane of the thermal insulation. With an insulated external wall, the window ideally sits at the outer masonry or in the insulation layer, and the frame is insulated over on the outside.
Do I have to insulate the reveal when replacing windows?
If the facade is insulated or will be insulated later, the reveal should be given an insulation strip on the outside. With an uninsulated wall there is less scope; a professional connection and, where appropriate, internal insulation of the reveal help.
Sources
- Wikipedia – Wärmebrücke (DIN 4108-2, fRsi, Wärmebrückenzuschlag)(opens in a new tab)
- ift Rosenheim – Update Montageleitfaden Fenster und Außentüren(opens in a new tab)
- ESanMV Anlage 4 – wärmebrückenminimierte und luftdichte Ausführung(opens in a new tab)
- Passipedia – Anforderungen an Fenster (Einbau)(opens in a new tab)