Roof Windows vs Vertical Windows: The Differences in Planning, Technology and Regulations
7 minutes read
Roof windows and vertical windows differ on almost every planning point: roof windows sit at a slope in the roof surface, are more heavily weathered, open differently and have their own energy requirements. In Germany, a maximum of Uw 1.4 W/(m²K) applies to roof windows when replaced and 1.3 W/(m²K) to vertical windows (as of September 2026). In return, they bring plenty of daylight into rooms under the roof. If you are converting a loft, you should deliberately combine both window types and clarify early which window forms the escape route.
The legal requirements below are German (federal energy law and the Berlin building code as an example). If you live elsewhere, please check your local building regulations.
Roof windows vs vertical windows: the differences
| Criterion | Roof window | Vertical window |
|---|---|---|
| Position | Sloping in the roof surface | Vertical in the wall |
| Light | Skylight from above | Side light, view of the surroundings |
| Opening | Centre-pivot, top-hung, exit windows | Tilt-and-turn, tilt, double-leaf, sliding |
| Maximum Uw when replaced (Germany) | 1.4 W/(m²K) | 1.3 W/(m²K) |
| Weathering | High: rain, snow, direct sun | Lower, depending on roof overhang |
| Installation | Flashing frame, connection to insulation and underlay | Connection to masonry or façade |
| Summer heat protection | External sun protection particularly important | Depends on orientation |
Daylight: why roof windows are so bright
A roof window looks at the sky and so catches plenty of diffuse light even in overcast weather. A vertical window in the gable, by contrast, brings side light and a view outside. In practice the two complement each other: the gable window provides the view, the roof window even brightness deep into the room.
For habitable rooms, building codes prescribe a minimum window size. In Berlin, under § 47 BauO Bln, habitable rooms must have windows with a rough opening of at least one eighth of the net floor area; habitable rooms in the roof space also need a clear height of 2.20 m over at least half their area. Other German states have similar rules, so check your state building code.
Opening types of roof windows
Centre-pivot windows: The sash is hung centrally in the frame and turns about a central axis. The handle is at the top. Roto names as an advantage that furniture such as chests of drawers or worktops can stand under the window; the outer pane can also be cleaned from inside.
Top-hung roof windows: The sash is operated with a handle at the bottom and swings open outwards. Roto highlights the free view, convenient ventilation and maximum headroom because no sash projects into the room.
Exit windows: They open wide and serve as access to the roof or as an escape route.
For vertical windows there are more variants, from the tilt-and-turn window to the lift-and-slide door. An overview is in Window opening types.
Escape route: the roof window as an emergency exit
In loft flats, a window often has to serve as a second escape route that is reachable for the fire brigade. The Berlin building code requires in § 37, for example:
- a clear opening of at least 0.90 m × 1.20 m (width × height),
- a parapet no more than 1.20 m above the floor,
- for windows in roof slopes: lower edge at most 1 m from the eaves (measured horizontally).
The requirements of the other German states are similar but not identical. Clarify with your designer and building control authority which window forms the escape route, and choose an exit window suited to it. This note does not replace fire-safety planning.
Energy: Uw-values and summer heat protection
When replacing windows, the following maximum values apply to residential buildings in Germany under Annex 7 of the Building Modernisation Act (successor to the GEG since 29 July 2026) (as of September 2026):
- Windows and window doors: Uw 1.3 W/(m²K)
- Roof windows: Uw 1.4 W/(m²K)
- Glass roofs: 2.0 W/(m²K)
Stricter values apply for funding; the Verbraucherzentrale gives Uw 0.95 W/(m²K) for funded windows and 1.0 W/(m²K) for roof windows. Details on funding are explained in BAFA funding for windows 2026.
In summer, roof spaces heat up quickly. A south-facing roof window without external sun protection can warm a room considerably. So plan heat-protection awnings or external roller shutters from the start. Read more in Avoiding overheating: summer heat protection.
Installation: two different trades
Vertical windows are fitted into the wall opening and connected to the masonry or façade airtight, driving-rain-tight and insulated. Roof windows sit in the roof structure: outside, a flashing frame provides the tight connection to tiles or sheet metal; inside, the window must be connected to the insulation, vapour barrier and interior lining. Roto stresses that a suitable installation frame ensures a tight connection between roof and window and so prevents draughts and mould.
Replacing a roof window is therefore often a job for a roofer or carpenter, replacing a vertical window one for the window fitter. How a vertical window is properly connected is explained in RAL installation: fitting windows correctly.
Dormers and gables: vertical windows in the roof
Not every window in the loft is a roof window. Vertical windows in gable walls and dormers are technically vertical windows, with all the advantages: a free view straight ahead, tilt-and-turn function, roller shutters and insect screens as in the rest of the house. They do, however, need a dormer or a gable wall in the right place.
Typical combinations in loft conversions:
- Gable window plus roof window: view at the end wall, light deep in the room.
- Dormer with vertical window: more standing height and a vertical window, but more structural work and, depending on size, permit questions.
- Roof window combinations: two roof windows side by side or one above the other; VELUX, for example, describes how two roof windows installed side by side bring twice as much daylight.
Installation height and operation
With roof windows, the installation height decides the view and ease of operation. If the window sits too high, you see only sky; if it sits too low, it interferes with the furnishing. With the top-hung roof window the handle is at the bottom, with the centre-pivot window at the top, which affects how well a window can be operated at the chosen height. Ask the manufacturer or roofer for the recommended installation height for your roof pitch. For windows set very high there are electric and solar-powered drives controlled by wall switch or remote.
Maintenance and care
Roof windows are exposed to rain, snow and sun more directly. VELUX recommends aftercare at least every four years for wooden roof windows, every two years under heavy exposure, and removing snow and ice in snowy regions. Vertical windows under a roof overhang are more sheltered.
Checklist for a loft conversion
- Which rooms need a view, which mainly light?
- Check the minimum window size under the state building code.
- Decide the escape route and choose a suitable exit window.
- Check the Uw-values for roof and vertical windows separately.
- Plan external sun protection for roof windows.
- Coordinate the trades: roofer, window fitter, interior finishing.
- Clarify operation: manual, electric or solar-powered, especially for roof windows set high.
- Prevent condensation: purge-ventilate loft rooms regularly, because warm, moist air rises and condenses on cold surfaces.
Vertical windows for your loft conversion
For gable and dormer windows, you will find made-to-measure windows in uPVC and aluminium in the configurator. The windows page shows the full range.
Frequently asked questions
Which U-values apply to roof windows when replaced in Germany?
Under Annex 7 of the German Building Modernisation Act (GModG), roof windows installed in residential buildings must not exceed a Uw-value of 1.4 W/(m²K), and vertical windows 1.3 W/(m²K) (as of September 2026). Readers elsewhere should check their local requirements.
What is the difference between a centre-pivot and a top-hung roof window?
The centre-pivot window turns about a central axis and is operated at the top; furniture under the window is no obstacle. The top-hung roof window is operated with a handle at the bottom, swings open outwards and gives a free view with no sash in the room.
Can a roof window serve as an escape route?
Yes, if it meets the requirements of the state building code. In Berlin, for example, escape windows must have a clear opening of at least 0.90 × 1.20 m; for windows in roof slopes, the lower edge may be at most 1 m from the eaves. There are special exit windows for this.
Do roof windows need more maintenance than vertical windows?
They are more heavily weathered. VELUX gives aftercare at least every four years for wooden roof windows, every two years under heavy exposure; snow and ice should be removed in heavy snowfall.
Sources
- Anlage 7 GModG – Höchstwerte der Wärmedurchgangskoeffizienten(opens in a new tab)
- BauO Bln § 37 Fenster, Türen, sonstige Öffnungen(opens in a new tab)
- BauO Bln § 47 Aufenthaltsräume(opens in a new tab)
- Roto: Klapp-Schwingfenster(opens in a new tab)
- Roto: Schwingfenster(opens in a new tab)
- VELUX: Dachfenster – Produktübersicht und Lichtlösungen(opens in a new tab)
- VELUX: Dachfenster – Bedienung, Pflege und Wartung(opens in a new tab)
- Verbraucherzentrale: Fenster sanieren oder austauschen – darauf sollten Sie achten (Stand 12.02.2026)(opens in a new tab)
- Verbraucherzentrale: Neue Fenster – energieeffizient und sicher planen (Stand 11.08.2026)(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.