Acoustic windows are divided under VDI 2719 into six sound insulation classes, from class 1 (Rw 25–29 dB) to class 6 (Rw from 50 dB). Standard insulating glass usually reaches class 2; for class 4 and above you need asymmetric glass build-ups, thicker panes or laminated glass with an acoustic interlayer. Which class you need depends on the outside noise and the use of the room, and the best value is of little use if the roller shutter box or the installation joint lets sound through. The classes and standards here (VDI 2719, DIN 4109) are German; the Rw value itself is an international measure, but readers in the UK or elsewhere should check which acoustic requirements apply locally, for example Approved Document E in England for certain buildings.
Acoustic windows: classes 1 to 6 at a glance
The measure of sound insulation is the weighted sound reduction index Rw in decibels. The division into classes comes from VDI guideline 2719:
| Class | Rw of the installed window | Typical situation (guide) |
|---|---|---|
| 1 | 25–29 dB | quiet residential location away from the road |
| 2 | 30–34 dB | residential street with little traffic |
| 3 | 35–39 dB | residential collector road, urban location |
| 4 | 40–44 dB | main road at some distance |
| 5 | 45–49 dB | main road, closer |
| 6 | from 50 dB | very busy roads, railway, near an airport |
The situation descriptions are a rough guide. In an individual case, traffic volume, distance, speed, road surface and screening by other buildings decide.
Why a few dB make a big difference
The decibel scale is logarithmic. A difference of 10 dB is generally perceived as about half or twice as loud. The step from class 2 to class 4, roughly 10 dB, is therefore clearly audible indoors.
VDI 2719 and DIN 4109: not the same thing
The VDI 2719 classes are common in the trade because they are easy to understand. For building projects with legal sound insulation requirements, however, DIN 4109 "Sound insulation in buildings" is what counts. It derives from the relevant outside noise level which sound reduction index the entire external facade of a room must achieve, including wall, window, roller shutter box and vents.
The specialist literature points out that values determined under VDI 2719 must not be equated with the requirements of DIN 4109; depending on the method, differences of several classes can arise. For new builds in noise-affected areas, the development plan often requires a sound insulation assessment. The building control authority and the development plan have the last word; this article does not replace legal or specialist design advice.
How a window insulates sound
Sound is transmitted through glass, frame and all joints. The main levers:
- Mass: thicker panes attenuate more.
- Asymmetry: panes of different thickness vibrate at different frequencies and prevent resonances from adding up.
- Cavity width: a wider gap improves insulation.
- Laminated glass with acoustic interlayer: a special interlayer damps vibrations particularly effectively.
- Seals: several all-round sealing planes and sufficient contact pressure are a prerequisite. Windows with a centre seal have advantages here, see centre seal in windows.
Typical glass build-ups by class:
| Class | Typical glass build-up (examples) |
|---|---|
| 2 | standard insulating glass, e.g. 4/16/4 mm |
| 3 | asymmetric double or triple glazing |
| 4 and higher | thicker panes, laminated safety glass with acoustic interlayer |
Triple glazing is not automatically quieter. With panes of equal thickness it can even perform worse than an asymmetric double glazing unit. For good thermal and sound insulation, both requirements are optimised together. Under the German ESanMV and BEG requirements, windows with special glazing for sound insulation may have a Uw of up to 1.1 W/(m²K) if they are to be funded.
The weak points: roller shutter box, vents and joint
A class 4 window achieves little if an uninsulated roller shutter box sits next to it. Watch out for:
- Roller shutter boxes: they are often the weakest link. Boxes with sound insulation, or surface-mounted roller shutters where the box sits outside, help. More in the article on types of roller shutter.
- Vents: rebate vents and wall air inlets create an air path, and with it a sound path. On noisy facades, choose sound-attenuated versions.
- Installation joint: the German RAL installation guideline requires that the joint seal does not worsen the window's sound insulation by more than 1 dB. Voids and unfilled joints are genuine sound bridges.
- Tilt position: a tilted window loses most of its sound insulation.
More than the number: frequencies and types of noise
The Rw value summarises the insulation across many frequencies in one number. But noise is not all alike. Urban road traffic contains many low frequencies, such as the rumble of lorries and buses. Rail traffic and fast roads have a different spectrum. That is why there are so-called spectrum adaptation terms, which state how well a window works against particular types of noise. For low-frequency road noise, an asymmetric build-up with a wider cavity is often helpful.
In practice that means two windows with the same Rw can sound different on an inner-city street. For demanding locations, ask for the complete test values.
Test value and installed value
Sound insulation values are determined on a test rig. In the building, influences such as the installation joint, roller shutter box and wall construction come into play. Designers therefore calculate with safety margins so that the installed window reliably achieves the required insulation. If a sound insulation assessment demands a particular value, agree with the designer which test value must be ordered.
What occupants can do themselves
- Have the windows adjusted regularly so that the seals sit evenly
- Replace worn seals
- Seal the roller shutter box cover on the inside
- Place bedrooms on the quiet side where possible
- With night-time noise, avoid the tilt position and solve ventilation through sound-attenuated vents or airing in short bursts in the evening
- Heavy curtains reduce reverberation in the room but do not improve the insulation of the window itself
How to choose the right class
- Assess the noise source: road, rail, commercial, air traffic; day and night. Many local authorities publish noise maps that give a first indication.
- Prioritise rooms: bedrooms and children's rooms on the noisy side need the highest protection.
- Distinguish facades: the quiet rear often manages with a lower class.
- Check requirements: for new builds and conversions, note the development plan and any sound insulation assessment.
- Plan the whole system: match roller shutter box, ventilation and installation to the class.
Sound insulation and funding
Acoustic windows can be funded if they meet the energy requirements. For windows with special glazing for sound insulation, the ESanMV sets a Uw of no more than 1.1 W/(m²K) (status: September 2026). In addition, some airports, motorways and railway lines in Germany have their own noise protection programmes run by operators or local authorities that subsidise acoustic windows. Whether your house is in such an area is something you can find out from your municipality or the operator of the facility. Combination with other funding is restricted depending on the programme.
Checklist for your enquiry
- State the desired sound insulation class or Rw value for each room
- Include roller shutter box and vents
- Consider glass build-up and Uw value together
- Agree installation under the RAL guideline, see RAL installation
- Where noise requirements apply, present the designer's assessment
You can choose profile and glazing in the configurator; for special acoustic build-ups or values from a sound insulation assessment, our team can help via the contact page.
Frequently asked questions
Which sound insulation class do I need for my window?
That depends on the outside noise, the use of the room and the position on the facade. On quiet residential streets, class 2 or 3 is often enough; on main roads, higher classes are needed. For new builds with noise requirements, the value comes from the sound insulation assessment under DIN 4109.
What does the Rw value mean for windows?
Rw is the weighted sound reduction index in decibels. It states by how much a component attenuates sound. A higher value means better sound insulation; because the decibel scale is logarithmic, even a few dB of difference are clearly audible.
Is ordinary double glazing sound-insulating?
Standard insulating glass with a symmetrical build-up typically reaches sound insulation class 2. For higher classes, asymmetric build-ups, thicker panes or laminated glass with an acoustic interlayer are used.
Is triple glazing automatically better for sound insulation?
Not automatically. Triple glazing with panes of equal thickness does not necessarily insulate sound better than a good double glazing unit. What matters are different pane thicknesses, cavity widths and, where appropriate, acoustic interlayers.
Sources
- energie-experten.org – Schallschutz von Fenstern nach VDI 2719(opens in a new tab)
- fensterblick.de – Schallschutzklassen für Fenster und Verglasung(opens in a new tab)
- ift Rosenheim – Update Montageleitfaden Fenster und Außentüren(opens in a new tab)
- ESanMV Anlage 4 – Sonderverglasungen (Schallschutz) Uw ≤ 1,1(opens in a new tab)
Ready for your project?
Configure your products to measure and see the price straight away – or send us your questions.